MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW USING C15O2 AND POSITRON EMISSION TOMOGRAPHY - COMPARISON OF TRACER MODELS

被引:36
|
作者
LAMMERTSMA, AA
DESILVA, R
ARAUJO, LI
JONES, T
机构
[1] MRC Cyclotron Unit, Hammersmith Hospital, London
来源
关键词
D O I
10.1088/0143-0815/13/1/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Eight different modifications of the same single tissue compartment model to measure myocardial blood flow, based on inhalation of O-15-labelled CO2 and positron emission tomography, were assessed in both dogs and human normal volunteers. Several models provided results with the same degree of accuracy in dogs. However, a number of these models gave poorer results in humans. It was established that the model containing components for blood flow, fraction of water exchanging tissue and spill-over arterial blood volume provided the most accurate and reproducible results. This model contains inherent corrections for the limited spatial resolution of positron emission tomographs. For ease of computation, linearisation of the operational (fitting) equation was tested, but found not to be satisfactory. The left atrium was slightly better than the left ventricle for determining the arterial input function. Inclusion of the blood volume term in the fitting procedure was significantly better than subtracting blood volume prior to analysis, both in terms of accuracy and precision.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [21] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW (RCBF) BY POSITRON EMISSION TOMOGRAPHY USING WATER-O-15 - VALIDATION OF AN INVIVO AUTORADIOGRAPHIC PARADIGM
    GINSBERG, MD
    LOCKWOOD, AH
    BUSTO, R
    FINN, RD
    CLARK, JC
    NEUROLOGY, 1981, 31 (04) : 131 - 131
  • [22] CEREBRAL BLOOD-FLOW MEASUREMENT BY POSITRON EMISSION TOMOGRAPHY
    DUNCAN, CC
    BENNETT, GW
    MENT, LR
    ACTA NEUROCHIRURGICA, 1982, 64 (3-4) : 273 - 273
  • [23] A SYSTEM FOR CEREBRAL BLOOD-FLOW MEASUREMENT USING AN (H2O)-O-15 AUTORADIOGRAPHIC METHOD AND POSITRON EMISSION TOMOGRAPHY
    KANNO, I
    IIDA, H
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    SASAKI, H
    INUGAMI, A
    SHISHIDO, F
    UEMURA, K
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (02): : 143 - 153
  • [24] A STUDY OF THE SINGLE COMPARTMENT TRACER KINETIC-MODEL FOR THE MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW USING O-15-WATER AND POSITRON EMISSION TOMOGRAPHY
    GAMBHIR, SS
    HUANG, SC
    HAWKINS, RA
    PHELPS, ME
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (01): : 13 - 20
  • [25] MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW BY POSITRON COMPUTED-TOMOGRAPHY - VALIDATION AND LIMITATIONS
    YONEKURA, Y
    TAMAKI, N
    TORIZUKA, K
    TANAKA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1984, 48 (08): : 766 - 766
  • [26] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW DURING VOLITIONAL BREATHING USING POSITRON EMISSION TOMOGRAPHY IN MAN
    COLEBATCH, JG
    ADAMS, L
    MURPHY, K
    MARTIN, AJ
    LAMMERTSMA, AA
    TOCHONDANGUY, HJ
    CLARK, JC
    FRISTON, KJ
    GUZ, A
    JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P24 - P24
  • [27] ERROR PROPAGATION IN THE DETERMINATION OF CEREBRAL BLOOD-FLOW WITH THE INHALATION OF C15O2
    JONES, SC
    REIVICH, M
    GREENBERG, JH
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 606 - 606
  • [28] QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW AND FLOW RESERVE IN CHILDREN WITH KAWASAKI-DISEASE USING POSITRON EMISSION TOMOGRAPHY
    MUZIK, O
    PARIDON, SM
    MULLA, NF
    DAYANIKLI, F
    CIRCULATION, 1994, 90 (04) : 531 - 531
  • [29] MEASUREMENT OF BLOOD-FLOW IN TIBIAL FRACTURE PATIENTS USING POSITRON EMISSION TOMOGRAPHY
    ASHCROFT, GP
    EVANS, NTS
    ROEDA, D
    DODD, M
    MALLARD, JR
    PORTER, RW
    SMITH, FW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05): : 673 - 677
  • [30] IODOANTIPYRINE-C-11 FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW BY POSITRON EMISSION TOMOGRAPHY - VALIDATION STUDIES
    GINSBERG, MD
    LOCKWOOD, AH
    BUSTO, R
    FINN, RD
    CAMPBELL, JA
    BOOTHE, TE
    STROKE, 1981, 12 (06) : 745 - 750