MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW USING C15O2 AND POSITRON EMISSION TOMOGRAPHY - COMPARISON OF TRACER MODELS

被引:36
|
作者
LAMMERTSMA, AA
DESILVA, R
ARAUJO, LI
JONES, T
机构
[1] MRC Cyclotron Unit, Hammersmith Hospital, London
来源
关键词
D O I
10.1088/0143-0815/13/1/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Eight different modifications of the same single tissue compartment model to measure myocardial blood flow, based on inhalation of O-15-labelled CO2 and positron emission tomography, were assessed in both dogs and human normal volunteers. Several models provided results with the same degree of accuracy in dogs. However, a number of these models gave poorer results in humans. It was established that the model containing components for blood flow, fraction of water exchanging tissue and spill-over arterial blood volume provided the most accurate and reproducible results. This model contains inherent corrections for the limited spatial resolution of positron emission tomographs. For ease of computation, linearisation of the operational (fitting) equation was tested, but found not to be satisfactory. The left atrium was slightly better than the left ventricle for determining the arterial input function. Inclusion of the blood volume term in the fitting procedure was significantly better than subtracting blood volume prior to analysis, both in terms of accuracy and precision.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [1] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW BY CONTINUOUS INHALATION OF C15O2 USING POSITRON EMISSION TOMOGRAPHY
    STEINLING, M
    BARON, JC
    JOURNAL DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1982, 6 (03): : 89 - 95
  • [2] THE MEASUREMENT OF REGIONAL PULMONARY BLOOD-FLOW USING POSITRON EMISSION TOMOGRAPHY AND O-15 WATER
    MINTUN, MA
    MARKLIN, GF
    GREEN, MA
    SCHUSTER, DP
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P60 - P60
  • [3] QUANTITATIVE MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW USING DYNAMIC POSITRON EMISSION TO TOMOGRAPHY
    TAKAHASHI, A
    ONO, Y
    SUTOU, M
    UEMURA, K
    SHISHIDO, F
    KADOWAKI, K
    KUMAGAI, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (08): : 888 - 888
  • [4] QUANTITATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY POSITRON EMISSION TOMOGRAPHY
    WISENBERG, G
    SCHELBERT, H
    HOFFMAN, E
    HUANG, H
    PHELPS, M
    SKORTON, D
    CHILD, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 465 - 465
  • [5] ACCURATE INVIVO MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW BY POSITRON EMISSION TOMOGRAPHY (PET)
    CORN, C
    YONEKURA, H
    TANAKA, T
    LINKS, J
    WAGNER, H
    BECKER, L
    CIRCULATION, 1983, 68 (04) : 179 - 179
  • [6] POSITRON IMAGING OF CEREBRAL BLOOD-FLOW DURING CONTINUOUS INHALATION OF C15O2
    ACKERMAN, RH
    SUBRAMANYAM, R
    CORREIA, JA
    ALPERT, NM
    TAVERAS, JM
    STROKE, 1980, 11 (01) : 45 - 49
  • [7] USE OF POSITRON EMISSION TOMOGRAPHY TO QUANTIFY REGIONAL MYOCARDIAL BLOOD-FLOW
    WISENBERG, G
    SCHELBERT, H
    SELIN, C
    HOFFMAN, E
    HUANG, H
    PHELPS, M
    CIRCULATION, 1979, 60 (04) : 268 - 268
  • [8] POSITRON EMISSION TOMOGRAPHY AND THE QUANTITATIVE ASSESSMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW
    SOUFER, R
    ZARET, BL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (01) : 128 - 130
  • [9] QUANTITATIVE MEASUREMENT OF REGIONAL PULMONARY BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY
    MINTUN, MA
    TERPOGOSSIAN, MM
    GREEN, MA
    LICH, LL
    SCHUSTER, DP
    JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (01) : 317 - 326
  • [10] A COMPARISON BETWEEN REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS OBTAINED IN HUMAN-SUBJECTS USING C-11 METHYLALBUMIN MICROSPHERES, THE C15O2 STEADY-STATE METHOD, AND POSITRON EMISSION TOMOGRAPHY
    BROOKS, DJ
    FRACKOWIAK, RSJ
    LAMMERTSMA, AA
    HEROLD, S
    LEENDERS, KL
    SELWYN, AP
    TURTON, DR
    BRADY, F
    JONES, T
    ACTA NEUROLOGICA SCANDINAVICA, 1986, 73 (04): : 415 - 422