VAPOR-PRESSURE OF DIFLUOROMETHANE (HFC-32)

被引:11
|
作者
ZHU, MS
LI, J
WANG, BX
机构
[1] Department of Thermal Engineering, Tsinghua University, Beijing, 100084, P.R.
关键词
BURNETT APPARATUS; HFC-32; REFRIGERANTS; VAPOR PRESSURE;
D O I
10.1007/BF02431286
中图分类号
O414.1 [热力学];
学科分类号
摘要
A slightly modified Burnett apparatus has been used to measure 32 vapor-pressure data for HFC-32 in the temperature range from 273.39 to 347.29 K. The uncertainties of temperature and pressure are estimated to be within +/-10 mK and +/-500 Pa, respectively. The purity of the sample used in this work is 99.95%. On the basis of our data and of data from the literature, a vapor-pressure equation for HFC-32 is also proposed.
引用
收藏
页码:1221 / 1227
页数:7
相关论文
共 50 条