DIRECT DIGITAL MAMMOGRAPHY USING A SCANNED-SLOT CCD IMAGING-SYSTEM

被引:0
|
作者
YAFFE, MJ
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO,ON,CANADA
[2] UNIV TORONTO,DEPT RADIOL,TORONTO M5S 1A1,ON,CANADA
关键词
BREAST IMAGING; DIGITAL; MAMMOGRAPHY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, the rationale for digital mammography is presented in terms of the limitations of conventional mammography. Various approaches to digital image acquisition are discussed and the design of a scanned-slot digital mammography system currently under development is described. Preliminary results including an image of an anthropomorphic breast phantom are presented.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [1] A CLINICAL SCANNED-SLOT DIGITAL MAMMOGRAPHY PROTOTYPE
    MAIDMENT, AD
    STARKOSKI, BG
    MAWDSLEY, GE
    SOUTAR, IC
    PLEWES, DB
    YAFFE, MJ
    RADIOLOGY, 1992, 185 : 249 - 249
  • [2] Clinical evaluation of a scanned-slot, full field digital mammography system
    Feig, SA
    Yaffe, MJ
    Plewes, DB
    Maidment, ADA
    Piccaro, MF
    Tesic, M
    Mawdsley, GE
    Critten, JP
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 71 - 79
  • [3] A DIGITAL RADIOGRAPHIC IMAGING-SYSTEM FOR MAMMOGRAPHY
    FRITZ, SL
    CHANG, CHJ
    GUPTA, NK
    MARTIN, NL
    LAWS, RL
    ANDERSON, WH
    DWYER, SJ
    TEMPLETON, AW
    BERNARDI, R
    FOX, T
    INVESTIGATIVE RADIOLOGY, 1986, 21 (07) : 581 - 583
  • [4] A slot-scanned photodiode-array/CCD hybrid detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Tümer, T
    Yaffe, MJ
    MEDICAL PHYSICS, 2002, 29 (02) : 214 - 225
  • [5] A DIGITAL COLOR CCD IMAGING-SYSTEM USING CUSTOM VLSI CIRCUITS
    PARULSKI, KA
    HIBBARD, RH
    DLUNA, LJ
    SHELLEY, PR
    KENNEY, TJ
    VINCENT, JA
    IEEE 89 INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS: DIGEST OF TECHNICAL PAPERS, 1989, 8 : 182 - 183
  • [6] A DIGITAL COLOR CCD IMAGING-SYSTEM USING CUSTOM VLSI CIRCUITS
    PARULSKI, KA
    DLUNA, LJ
    HIBBARD, RH
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1989, 35 (03) : 382 - 389
  • [7] A CdZnTe slot-scanned detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Gordon, EE
    Hamilton, WJ
    Tümer, TO
    Yaffe, MJ
    MEDICAL PHYSICS, 2002, 29 (12) : 2767 - 2781
  • [8] Full field digital mammography with a CCD based slot-scanned detector. Physical characteristics measurement
    Tahoces, PG
    Nishikawa, RM
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 51 - 53
  • [9] COLOR IMAGING-SYSTEM USING A SINGLE CCD AREA ARRAY
    DILLON, PLP
    LEWIS, DM
    KASPAR, FG
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1978, 25 (02) : 102 - 107
  • [10] COLOR IMAGING-SYSTEM USING A SINGLE CCD AREA ARRAY
    DILLON, PLP
    LEWIS, DM
    KASPAR, FG
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1978, 13 (01) : 28 - 33