Geometry Effects of Capillary on the Evaporation from the Meniscus

被引:0
|
作者
Choi, Choonghyo
Jin, Songwan
Yoo, Jung Yul
机构
关键词
Evaporation; Meniscus; Corner Meniscus;
D O I
10.3795/KSME-B.2007.31.4.313
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of capillary cross-section geometry on evaporation is investigated in terms of the meniscus shape, evaporation rate and evaporation-induced flow for circular, square and rectangular cross-sectional capillaries. The shapes of water and ethanol menisci are not much different from each other in square and rectangular capillaries even though the surface tension of water is much larger than that of ethanol. On the other hand, the shapes of water and ethanol menisci are very different from each other in circular capillary. The averaged evaporation fluxes in circular and rectangular capillaries are measured by tracking the meniscus position. At a given position, the averaged evaporation flux in rectangular capillaries is much larger than that in circular capillary with comparable hydraulic diameter. The flow near the evaporating meniscus is also measured using micro-PIV, so that the rotating vortex motion is observed near the evaporating ethanol and methanol menisci except for the case of methanol meniscus in rectangular capillary. This difference is considered to be due to the existence of corner menisci at the four corners.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [1] Effects of cross-section geometry of capillary on the evaporation from the meniscus
    Jin, Songwan
    Choi, Choonghyo
    Breuer, Kenneth S.
    Yoo, Jung Yul
    ICMM 2005: 3rd International Conference on Microchannels and Minichannels, Pt B, 2005, : 191 - 197
  • [2] On the role of meniscus geometry in capillary wave generation
    X. Shao
    C. T. Gabbard
    J. B. Bostwick
    J. R. Saylor
    Experiments in Fluids, 2021, 62
  • [3] On the role of meniscus geometry in capillary wave generation
    Shao, X.
    Gabbard, C. T.
    Bostwick, J. B.
    Saylor, J. R.
    EXPERIMENTS IN FLUIDS, 2021, 62 (03)
  • [4] Experimental study of effects of volumetric porosity and critical meniscus radius on evaporation/boiling from thin capillary wicks
    Li, Chen
    Peterson, G. P.
    PROCEEDINGS OF THE ASME HEAT TRANSFER DIVISION 2005, VOL 2, 2005, 376-2 : 503 - 510
  • [5] ANALYSIS ON EVAPORATION OF THE EXTENDED THIN FILM MENISCUS IN CAPILLARY MICROSTRUCTURE
    Du, Xiaoze
    Yang, Lijun
    Yang, Yongping
    Zhao, Na
    Xian, Haizhen
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 2, 2009, : 55 - 62
  • [6] Fluid flow effects in evaporation from liquid-vapor meniscus
    Khrustalev, D
    Faghri, A
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 725 - 730
  • [7] EVAPORATION FROM A 2-DIMENSIONAL MENISCUS
    WEHRLE, VA
    VOULELIKAS, G
    AIAA JOURNAL, 1985, 23 (02) : 309 - 313
  • [8] EVAPORATION FROM A CAPILLARY TUBE
    PREISS, G
    WAYNER, PC
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02): : 178 - 181
  • [9] Evaporation heat transfer of thin liquid film and meniscus in micro capillary and on substrate with nanorelief
    Qu, W
    Zhang, LC
    Ma, T
    Ge, XS
    JOURNAL OF ENHANCED HEAT TRANSFER, 2003, 10 (02) : 131 - 148
  • [10] DETERMINING CAPILLARY CONSTANT OF A LIQUID FROM MENISCUS
    KHANTADZ.DV
    CHANTURI.ZA
    ONIKASHV.EG
    TSERTSVA.TG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (01): : 266 - &