INCREASING THE SIGNAL-TO-NOISE RATIO IN AMPEROMETRY AND POLAROGRAPHY USING THE CONTROLLED-GROWTH MERCURY DROP ELECTRODE

被引:3
|
作者
KOWALSKI, Z
MIGDALSKI, J
机构
[1] Academy of Mining and Metallurgy, Department of Analytical Chemistry, 30-059 Kraków
关键词
D O I
10.1016/0039-9140(94)80127-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach to current sampling in amperometric and polarographic measurement is described. This approach requires the application of a step-by-step mode of mercury drop generation. The advantages are: (1) in amperometric measurements an increase of the signal to noise ratio; (2) in polarographic measurements and computer aided experiments the noise level can be markedly reduced.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 50 条
  • [1] APPLICATION OF A CONTROLLED-GROWTH MERCURY DROP ELECTRODE TO POLAROGRAPHY
    KOWALSKI, Z
    ANALYST, 1988, 113 (01) : 15 - 19
  • [2] CONTROLLED-GROWTH MERCURY DROP ELECTRODE
    KOWALSKI, Z
    WONG, KH
    OSTERYOUNG, RA
    OSTERYOUNG, J
    ANALYTICAL CHEMISTRY, 1987, 59 (17) : 2216 - 2218
  • [3] STRIPPING ANALYSIS ON CONTROLLED-GROWTH MERCURY DROP ELECTRODE
    KOWALSKI, Z
    MIGDALSKI, J
    ELECTROANALYSIS, 1992, 4 (09) : 915 - 919
  • [4] STRIPPING ANALYSIS ON CONTROLLED-GROWTH MERCURY DROP ELECTRODE
    KOWALSKI, Z
    MIGDALSKI, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 623 - 624
  • [5] Mercury disk ultramicroelectrode based on the controlled-growth mercury drop system
    Zon, A
    Palys, M
    Stojek, Z
    CHEMIA ANALITYCZNA, 2002, 47 (03): : 361 - 369
  • [6] RAPID POLAROGRAPHY USING A VIBRATING MERCURY DROP ELECTRODE
    MAIRANOV.VG
    INDUSTRIAL LABORATORY, 1965, 31 (10): : 1482 - &
  • [7] INCREASING SIGNAL-TO-NOISE RATIO IN RECORDING OF FM SIGNALS
    KOMAROV, VA
    TELECOMMUNICATIONS AND RADIO ENGINEER-USSR, 1969, (06): : 71 - &
  • [8] USE OF CONTROLLED DROP TIME MERCURY ELECTRODE IN ALTERNATING CURRENT POLAROGRAPHY
    ZATKA, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 27 (01): : 164 - &
  • [9] Signal-to-noise ratio improvement in multiple electrode recording
    Musial, PG
    Baker, SN
    Gerstein, GL
    King, EA
    Keating, JG
    JOURNAL OF NEUROSCIENCE METHODS, 2002, 115 (01) : 29 - 43
  • [10] Measurement of Signal-to-Noise Ratio and Signal-to-Noise and Distortion Ratio Using Histogram Test in Time Domain Analysis
    Jain, Manish
    Sharma, Prakash Chandra
    Tiwari, Pradeep Kumar
    Gupta, Rohit Kumar
    SMART SYSTEMS: INNOVATIONS IN COMPUTING (SSIC 2021), 2022, 235 : 403 - 410