R-R Interval Outlier Processing for Heart Rate Variability Analysis using Wearable ECG Devices

被引:15
|
作者
Eguchi, Kana [1 ,3 ]
Aoki, Ryosuke [1 ]
Shimauchi, Suehiro [2 ]
Yoshida, Kazuhiro [1 ]
Yamada, Tomohiro [1 ]
机构
[1] NTT Corp, NTT Serv Evolut Labs, Yokosuka, Kanagawa, Japan
[2] NTT Corp, NTT Media Intelligence Labs, Tokyo, Japan
[3] NTT Yokosuka R&D Ctr, Y-509A,1-1 Hikari No Oka, Yokosuka, Kanagawa 2390847, Japan
关键词
wearable; electrocardiogram; heart rate variability; measurement fault; outlier processing;
D O I
10.14326/abe.7.28
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrocardiograms (ECGs) captured by wearable ECG devices readily contain artifacts due to measurement faults. Since artifacts and R waves have quite similar frequency characteristics, R wave misdetection or R-R interval (RRI) miscalculation may result. Aiming at accurate analysis of heart rate variability (HRV), this paper proposes a new RRI outlier processing method consisting of three steps: evaluating RRI reliability, excluding RRI outlier, and complementing missing RRI. In the first step, the method evaluates the measurement status of all detected R waves and calculates RRI reliability based on the measurement status of a combination of the measurement status of two R waves. Since we target wearable ECG devices used in non-medical environment, the method evaluates R waves based on the threshold electric potential for left ventricular hypertrophy, and determines those exceeding the threshold as artifacts. The method accordingly sets lower reliability to RRIs containing R waves evaluated as artifacts. In the second step, the method excludes all RRIs with low reliability as outliers. These steps may be effective for HRV measures in the time domain, but are not sufficient for analyzing HRV measures in the frequency domain. Resampling the time series RRI data, which is essential for analyzing HRV in the frequency domain, may produce outliers if the target RRIs contain missing values. Our method accordingly complements missing RRIs before data resampling based on RRI characteristics. We postulate that consecutive changes in RRIs follow a simple formula consisting of three components: direct current, low frequency, and high frequency. Our method complements missing values according to the formula, which is calculated from RRIs time series regarded as having been properly measured. To confirm the effectiveness of the method before applying it to ECGs recorded by wearable devices, we evaluated all the steps using pseudo-ECGs generated artificially by adding noise and artifacts to open ECG data. Initial evaluation results showed that the proposed method outperformed conventional method regarding the precision of both time and frequency domain measures of HRV.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 50 条
  • [1] Practical R-R Interval Editing for Heart Rate Variability Analysis Using Single-Channel Wearable ECG Devices
    Eguchi, Kana
    Aoki, Ryosuke
    IEEE ACCESS, 2023, 11 : 25543 - 25582
  • [2] Reliability Evaluation of R-R Interval Measurement Status for Time Domain Heart Rate Variability Analysis with Wearable ECG Devices
    Eguchi, Kana
    Aoki, Ryosuke
    Yoshida, Kazuhiro
    Yamada, Tomohiro
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1307 - 1311
  • [3] R-R Interval Outlier Exclusion Method Based on Statistical ECG Values Targeting HRV Analysis Using Wearable ECG Devices
    Eguchi, Kana
    Aoki, Ryosuke
    Yoshida, Kazuhiro
    Yamada, Tomohiro
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5689 - 5692
  • [4] Heart rate and heart rate variability in hypertension determined by R-R interval variations on electrocardiogram
    Catipovic-Veselica, K
    Kozul, K
    JOURNAL OF HYPERTENSION, 2002, 20 : S349 - S349
  • [5] EFFECTS OF AGE, HEART-RATE, GENDER, TOBACCO AND ALCOHOL INGESTION ON R-R INTERVAL VARIABILITY IN HUMAN ECG
    MURATA, K
    LANDRIGAN, PJ
    ARAKI, S
    JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1992, 37 (03): : 199 - 206
  • [6] Role of editing of R-R intervals in the analysis of heart rate variability
    Peltola, Mirja A.
    FRONTIERS IN PHYSIOLOGY, 2012, 3
  • [7] ECG as Biometric Using Autocorrelation of normalized R-R interval
    Javaid, Hafiza Saira
    Sheikh, Shahzad Amin
    2016 IEEE 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS (IS), 2016, : 698 - 701
  • [8] Effect of Different ECG Leads on Estimated R-R Intervals and Heart Rate Variability Parameters
    Jeyhani, Vala
    Mantysalo, Matti
    Noponen, Kai
    Seppanen, Tapio
    Vehkaoja, Antti
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3786 - 3790
  • [9] Alignment of R-R Interval Signals using the Circadian Heart Rate Rhythm
    Gayraud, Nathalie T. H.
    Manis, George
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3347 - 3350
  • [10] Using contexts and R-R interval estimation in lossless ECG compression
    Giurcaneanu, CD
    Tabus, I
    Mereuta, S
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2002, 67 (03) : 177 - 186