A study of false apical defects in myocardial perfusion imaging with SPECT/CT

被引:2
|
作者
Denisova, N. V. [1 ]
Ansheles, A. A. [2 ]
机构
[1] Russian Acad Sci, Siberian Branch, Khristianovich Inst Theoret & Appl Mech, Novosibirsk 630090, Russia
[2] Natl Med Res Ctr Cardiol, Moscow, Russia
来源
关键词
single photon emission computed tomography; nuclear cardiology; numerical simulations;
D O I
10.1088/2057-1976/aae414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An important problem of myocardial SPECT/CT imaging with attenuation correction (AC) is a reduction of radiotracer activity at the apex in reconstructed images. This problem is known as the false apical defect. False apical defects mask real defects and lead to interpretation uncertainties. The aim of the present work is to study this phenomenon to understand the cause of apical defects on AC images. Mathematical modeling and clinical studies are carried out. Special mathematical models were designed to study the effect of the myocardial left ventricle (LV) form and the effect of patient constitution on false apical defects severity. Computer simulations of the SPECT/CT myocardial perfusion imaging procedure with and without attenuation correction were performed. The dependence of apical false defects on the LV form and on the data acquisition scheme was studied. The results of mathematical modeling have shown that the cause of false apical defects is not associated with attenuation correction. Rather, it is related to the LV form, especially to the presence of anatomical apical thinning. The LV form with apical thinning in diastole phase can not be exactly reconstructed by using the standard data acquisition schemes with limited 32 and 60 views. The reconstruction error appears in the rounded apical region in reconstructions with and without attenuation correction. But, in non-AC images, this error is masked by the second error related to the lack of attenuation correction. Interpretation based on the results of two compensating errors cannot be reliable. Taking into account the results obtained, we suggest the following hypothesis: gated systolic AC images can be useful in the interpretations of findings at the apex. This hypothesis was confirmed in preliminary clinical study.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of the Extent and Severity of Myocardial Perfusion Defects Measured by CT Coronary Angiography and SPECT Myocardial Perfusion Imaging
    Tamarappoo, Balaji K.
    Dey, Damini
    Nakazato, Ryo
    Shmilovich, Haim
    Smith, Thomas
    Cheng, Victor Y.
    Thomson, Louise E. J.
    Hayes, Sean W.
    Friedman, John D.
    Germano, Guido
    Slomka, Piotr J.
    Berman, Daniel S.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (10) : 1010 - 1019
  • [2] SPECT Myocardial Perfusion Imaging in the Diagnosis of Apical Hypertrophic Cardiomyopathy
    Masrur, Shihab
    Memon, Sarfaraz
    Chhabra, Lovely
    Parker, Matthew W.
    Duvall, Lane
    TEXAS HEART INSTITUTE JOURNAL, 2016, 43 (05): : 467 - 468
  • [3] Comparison of IQ-SPECT/CT with conventional SPECT/CT for myocardial perfusion imaging
    Novak, Mackenzie
    Grancorvitz, Abigail
    Johnson, Carlyn
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [4] Reproducibility of reversible myocardial perfusion defects by cold pressor test myocardial perfusion SPECT imaging
    Masoli, O.
    Redruello, M.
    Maciel, N.
    Gagliardi, J.
    Traverso, S.
    Grynberg, L.
    Vidal, L.
    Balino, N. Perez
    CIRCULATION, 2008, 118 (12) : E384 - E384
  • [5] The performance of phase analysis of gated SPECT myocardial perfusion imaging in the presence of perfusion defects: A simulation study
    Alice Cheung
    Yanli Zhou
    Tracy L. Faber
    Ernest V. Garcia
    Lei Zhu
    Ji Chen
    Journal of Nuclear Cardiology, 2012, 19 : 500 - 506
  • [6] The performance of phase analysis of gated SPECT myocardial perfusion imaging in the presence of perfusion defects: A simulation study
    Cheung, Alice
    Zhou, Yanli
    Faber, Tracy L.
    Garcia, Ernest V.
    Zhu, Lei
    Chen, Ji
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 500 - 506
  • [7] Analysis of apical remodeling in gated myocardial perfusion SPECT imaging in ischemic cardiomyopathy
    Guillermo Romero-Farina
    Jaume Candell-Riera
    Santiago Aguadé-Bruix
    Joan Castell-Conesa
    Gustavo de León
    Journal of Nuclear Cardiology, 2008, 15 : 225 - 231
  • [8] Impact of CT Attenuation Correction in SPECT Myocardial Perfusion Imaging
    Vlachou, F.
    Nikaki, A.
    Gogos, K.
    Tsiakas, E.
    Papoutsani, D.
    Giannis, D.
    Gogou, L.
    Prassopoulos, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S317 - S317
  • [9] Effect of scattering correction on SPECT/CT myocardial perfusion imaging
    Huang, Kemin
    Feng, Yanlin
    Yu, Fengwen
    Liang, Weitang
    Li, Lin
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [10] Analysis of apical remodeling in gated myocardial perfusion SPECT imaging in ischemic cardiomyopathy
    Romero-Farina, Guillermo
    Candell-Riera, Jaurne
    Aguade-Bruix, Santiago
    Castell-Conesa, Joan
    de Leon, Gustavo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (02) : 225 - 231