A COMPUTER-CONTROLLED VENTILATOR WEANING SYSTEM

被引:32
|
作者
STRICKLAND, JH
HASSON, JH
机构
[1] Office of Medical Education, Baptist Med. Center Princeton, Birmingham
关键词
D O I
10.1378/chest.100.4.1096
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Weaning of patients from mechanical ventilation is a time-consuming, labor-intensive process. Because most weaning decisions are based on objective data, we tested a computer-directed weaning system on postoperative patients. We developed an automatic, computer-controlled ventilator weaning system which interfaces a laptop computer to a ventilator and a pulse oximeter. The laptop computer program accesses patient data through the ventilator and pulse oximeter to make weaning decisions. The computer directly controls the ventilator through an interface developed for this system. We tested the system in nine postoperative patients who met the following criteria: negative inspiratory force less-than-or-equal-to -20 cm H2O, vital capacity > 10 ml/kg, inspired oxygen concentration less-than-or-equal-to 40 percent, and satisfactory arterial blood gas parameters (pH between 7.32 and 7.48, PCO2 between 32 and 48, and oxygen saturation greater-than-or-equal-to 90 percent). The computer decreased the SIMV rate by 2 breaths/min every 5 min until a rate of 2 breaths/min was reached, then decreased pressure support by 4 cm H2O every 5 min as long as the patient met the following criteria: respiratory rate between 8 and 25 breaths/min, minute ventilation between 6 and 14 L, and pulse oximeter oxygen saturation greater-than-or-equal-to 90 percent. If unsatisfactory weaning criteria were noted, the system automatically returned the patient to the previous weaning level. We successfully weaned nine patients using the system. Additional studies are underway to determine if this system can be used in medical patients. We believe this computer-controlled ventilator weaning system can be used successfully in patients requiring mechanical ventilation and may decrease the time and cost associated with the care of these patients.
引用
收藏
页码:1096 / 1099
页数:4
相关论文
共 50 条
  • [1] A COMPUTER-CONTROLLED VENTILATOR WEANING SYSTEM - A CLINICAL-TRIAL
    STRICKLAND, JH
    HASSON, JH
    CHEST, 1993, 103 (04) : 1220 - 1226
  • [2] Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator
    Cruz, Andrea F.
    Herrmann, Jacob
    Hajdarevic, Bakir
    Hawley, Monica L.
    Fox, Donald
    Bates, Jason H. T.
    Kaczka, David W.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2025, 19 (01):
  • [3] The static pressure-volume relationship of the respiratory system determined with a computer-controlled ventilator
    Svantesson, C
    Drefeldt, B
    Jonson, B
    CLINICAL PHYSIOLOGY, 1997, 17 (04): : 419 - 430
  • [4] A computer-controlled voltametry system
    不详
    TENSIDE SURFACTANTS DETERGENTS, 1999, 36 (01) : 28 - 28
  • [5] A COMPUTER-CONTROLLED STEREOTAXIC SYSTEM
    SIEGEL, L
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1969, BM16 (03) : 197 - &
  • [6] COMPUTER-CONTROLLED TELECONTROL SYSTEM
    BENEZ, H
    GORTZ, B
    TUCHEL, L
    SIEMENS ZEITSCHRIFT, 1978, 52 (11): : 601 - 605
  • [7] COMPUTER-CONTROLLED INTERLOCKING SYSTEM
    ANDERSSON, HS
    HAGELIN, G
    ERICSSON REVIEW, 1981, 58 (02): : 74 - 80
  • [8] A COMPUTER-CONTROLLED MICROFILM SYSTEM
    HAWKINSO.B
    DATAMATION, 1970, 16 (03): : 119 - &
  • [9] COMPUTER-CONTROLLED PULSER SYSTEM
    JENSEN, D
    KREISLER, M
    LOMANNO, F
    POSTER, R
    RABIN, M
    SMART, P
    WISE, J
    DAKIN, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (03): : 503 - 508
  • [10] A COMPUTER-CONTROLLED RESEARCH VENTILATOR FOR SMALL ANIMALS - DESIGN AND EVALUATION
    SCHUESSLER, TF
    BATES, JHT
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) : 860 - 866