SCALE-UP OF LABORATORY DATA FOR DISTILLATION-COLUMNS CONTAINING CORRUGATED METAL-TYPE STRUCTURED PACKING

被引:16
|
作者
HUFTON, JR [1 ]
BRAVO, JL [1 ]
FAIR, JR [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
Chemical Equipment - Performance - Mixtures - Testing;
D O I
10.1021/ie00083a023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Laboratory-scale measurements were made of the mass-transfer efficiency of a gauze-type distillation column packing. The test mixture, chlorobenzene/ethylbenzene, was used, and several operating pressures in the range 40-750 mmHg were studied. It was found that the HETP data were correlated well by available models developed for commercial-scale structured packings. The final result of the work is a procedure that enables tests at 25-mm column diameter size to be used for predicting performance of a large-scale system utilizing structured packing, gauze, or sheet metal.