CALCULATION OF THE MUTUAL INDUCTION BETWEEN COPLANAR CIRCULAR SURFACE COILS IN MAGNETIC-RESONANCE-IMAGING

被引:13
|
作者
KWIAT, D [1 ]
SAOUB, S [1 ]
EINAV, S [1 ]
机构
[1] TEL AVIV UNIV,FAC ENGN,BIOMED ENGN PROGRAM,IL-69978 TEL AVIV,ISRAEL
关键词
D O I
10.1109/10.135536
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The induced current in a coil due to the presence of alternating currents in an adjacent coil is calculated here for a case of two similar and coplanar, circular coils. By using an overlapping configuration, the mutual inductance is nullified as is predicted theoretically and confirmed experimentally.
引用
收藏
页码:433 / 436
页数:4
相关论文
共 50 条
  • [1] SOLENOID SURFACE COILS IN MAGNETIC-RESONANCE-IMAGING
    LUFKIN, RB
    VOTRUBA, J
    REICHER, M
    BASSETT, L
    SMITH, SD
    HANAFEE, WN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (02) : 409 - 412
  • [2] MAGNETIC-RESONANCE-IMAGING OF SYRINGOMYELIA USING SURFACE COILS
    GUILLEUX, MH
    BYDDER, GM
    STEINER, RE
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 808 - 808
  • [4] USE OF SURFACE COILS IN MAGNETIC-RESONANCE-IMAGING OF ORBIT AND KNEE
    BEYER, D
    STEINBRICH, W
    FRIEDMANN, G
    ERMERS, JWLM
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (1-2) : 84 - 91
  • [5] MAGNETIC-RESONANCE-IMAGING OF THE FACIAL-NERVE USING SURFACE COILS
    WORTHAM, DG
    LUFKIN, R
    WARD, PH
    TERESI, L
    HANAFEE, W
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1986, : 92 - 93
  • [6] INVESTIGATION OF TUMORS OF THE KNEE BY MAGNETIC-RESONANCE-IMAGING (MRI) WITH SURFACE COILS
    ROGER, B
    LAVALJEANTET, M
    DELEPINE, N
    DELEPINE, G
    TOBOLSKI, F
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1986, 72 (04): : 253 - 258
  • [7] DESIGN OF GRADIENT COILS FOR MAGNETIC-RESONANCE-IMAGING
    ADAMIAK, K
    RUTT, BK
    DABROWSKI, WJ
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (05) : 2403 - 2405
  • [8] INITIAL EXPERIENCE OF THE USE OF MAGNETIC-RESONANCE-IMAGING WITH SURFACE COILS IN ORBITAL DIAGNOSIS
    SCHLEVOGT, RK
    MAYER, UM
    REUTHER, G
    REQUARDT, H
    MEYTHALER, FH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1986, 189 (03) : 209 - 213
  • [9] PHASE AND SENSITIVITY OF RECEIVER COILS IN MAGNETIC-RESONANCE-IMAGING
    MCVEIGH, ER
    BRONSKILL, MJ
    HENKELMAN, RM
    MEDICAL PHYSICS, 1986, 13 (06) : 806 - 814
  • [10] INSERTABLE BIPLANAR GRADIENT COILS FOR MAGNETIC-RESONANCE-IMAGING
    MARTENS, MA
    PETROPOULOS, LS
    BROWN, RW
    ANDREWS, JH
    MORICH, MA
    PATRICK, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (11): : 2639 - 2645