EVALUATION OF THE GEL TEST FOR ANTIBODY SCREENING IN A TERTIARY HOSPITAL IN HONG-KONG - INSENSITIVITY FOR SOME COLD ANTIBODIES THAT ARE REACTIVE AT 37-DEGREES-C BY CONVENTIONAL INDIRECT ANTIGLOBULIN TESTS

被引:0
|
作者
CHENG, G
CHAN, A
CHUN, M
WONG, L
机构
来源
CLINICAL AND LABORATORY HAEMATOLOGY | 1995年 / 17卷 / 01期
关键词
ANTIGLOBULIN TEST; GEL TECHNIQUE; SENSITIVITY; ANTIBODY SCREENING;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The antiglobulin gel test (DiaMed) was compared with conventional IAT methods in pretransfusion antibody screening in a tertiary hospital in Hong Kong, Antibody titrations showed that the gel system was more sensitive than the tube IAT method in detecting anti-D, anti-S, anti-s, but slightly less sensitive with anti-E. The gel tests detected all clinically significant warm reacting allo-antibodies detected by conventional IAT methods except one case of weak anti-E. It detected a case of anti-C missed in conventional screening. The number of serological investigations due to false positive screens, non-specific antibodies and clinically insignificant cold antibodies (anti-P, and anti-Lewis) were reduced. The gel system was fast and easy to use. It would reduce delays and inconvenience caused to patients due to false positive screens and non-specific antibodies without compromising detection of clinically significant antibodies. However, of concern was the failure to detect several cases of anti-le(a) and anti-P-1 that were reactive at 37 degrees C by conventional IAT and one case of anti-H in a patient with Parabombay A.
引用
收藏
页码:81 / 84
页数:4
相关论文
empty
未找到相关数据