POLARIZED TRANSIENT HOT-WIRE THERMAL-CONDUCTIVITY MEASUREMENTS

被引:26
|
作者
PERKINS, RA [1 ]
LAESECKE, A [1 ]
DECASTRO, CAN [1 ]
机构
[1] UNIV LISBON,FAC CIENCIAS,DEPT QUIM,P-1700 LISBON,PORTUGAL
关键词
1-CHLORO-1,1-DIFLUOROETHANE; POLAR LIQUID; R134A; R142B; 1,1,1,2-TETRAFLUOROETHANE; THERMAL CONDUCTIVITY; TRANSIENT HOT WIRE INSTRUMENT;
D O I
10.1016/0378-3812(92)87074-W
中图分类号
O414.1 [热力学];
学科分类号
摘要
Additional experimental uncertainty is introduced in thermal conductivity data obtained with the transient hot-wire technique when bare hot wires are used in polar liquids. The use of a dc polarization voltage applied between the hot wires and the cell wall greatly reduces this uncertainty for polar liquids. Differences between polarized and nonpolarized experiments are described for the alternative refrigerants 1,1,1,2-tetrafluoroethane (R134a) and 1-chloro-1,1-difluoroethane (R142b). Comparisons are made between data from the polarized transient hot-wire technique and other experimental techniques for R142b. The polarization technique enables existing transient hot-wire instruments with bare wires to study the thermal conductivity of moderately polar liquids with confidence.
引用
收藏
页码:275 / 286
页数:12
相关论文
共 50 条