NONDIAGNOSTIC CT-GUIDED STEREOTAXIC BIOPSIES IN A SERIES OF 407 CASES - INFLUENCE OF CT MORPHOLOGY AND OPERATOR EXPERIENCE

被引:50
作者
RANJAN, A
RAJSHEKHAR, V
JOSEPH, T
CHANDY, MJ
CHANDI, SM
机构
[1] CHRISTIAN MED COLL & HOSP,DEPT NEUROL SCI,VELLORE 632004,TAMIL NADU,INDIA
[2] CHRISTIAN MED COLL & HOSP,DEPT PATHOL,VELLORE 632004,TAMIL NADU,INDIA
关键词
STEREOTAXIS; BIOPSY; COMPUTERIZED TOMOGRAPHY; MORPHOLOGY; OPERATOR EXPERIENCE;
D O I
10.3171/jns.1993.79.6.0839
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Nondiagnostic biopsies were analyzed in a consecutive series of 407 patients undergoing computerized tomography (CT)-guided stereotactic biopsies. These were categorized as either negative biopsies, when normal tissue or nonspecific pathology was found, or inconclusive, when a definitive diagnosis could not be made although representative tissue was obtained. Nineteen biopsies (4.7%) were negative and 10 (2.4%) were inconclusive, giving an overall nondiagnostic biopsy rate of 7.1% (29 of the 407 cases). Suspected neoplastic masses (390 cases) were classified on the basis of their CT morphology into four groups: Group 1 included purely hypodense nonenhancing masses; Group 2 included isodense nonenhancing masses; Group 3 included ring-enhancing masses; and Group 4 included mixed-density enhancing masses. Although a higher proportion of hypodense nonenhancing masses (six of 56, or 10.7%) yielded a negative result, there was no statistically significant difference in the negative biopsy rates for the different CT categories (p = 0.06). The negative biopsy rates for the 6 years of the study, 1987 to 1992 (1987 being an incomplete year) were as follows: 13.3%, 6%, 3.2%, 3%, 5.8%, and 2.7%. There was no significant decrease in the negative biopsy rate as experience with this procedure increased (p = 0.20). A total of eight surgeons independently performed the biopsies. There was no significant difference (p = 0.24) in the negative biopsy rate of the surgeon with the most experience (124 biopsies, 2.4% negative biopsy rate) compared with that of the seven other surgeons combined (283 biopsies; 5.7% negative biopsy rate). These findings suggest that the yield in a stereotactic biopsy is independent of the CT appearance of the mass. Adherence to certain basic principles in patient and target selection will ensure a reasonable percentage of positive yield with stereotactic biopsy procedures even if the surgeon is relatively inexperienced. There does not appear to be a learning curve in the performance of CT-guided stereotactic biopsies. The management of patients with nondiagnostic biopsies is discussed.
引用
收藏
页码:839 / 844
页数:6
相关论文
共 11 条
[1]   COMPUTED IMAGING STEREOTAXY - EXPERIENCE AND PERSPECTIVE RELATED TO 500 PROCEDURES APPLIED TO BRAIN MASSES [J].
APUZZO, MLJ ;
CHANDRASOMA, PT ;
COHEN, D ;
ZEE, CS ;
ZELMAN, V .
NEUROSURGERY, 1987, 20 (06) :930-937
[2]   SINGLE SMALL ENHANCING CT LESIONS IN INDIAN PATIENTS WITH EPILEPSY - CLINICAL, RADIOLOGICAL AND PATHOLOGICAL CONSIDERATIONS [J].
CHANDY, MJ ;
RAJSHEKHAR, V ;
GHOSH, S ;
PRAKASH, S ;
JOSEPH, T ;
ABRAHAM, J ;
CHANDI, SM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1991, 54 (08) :702-705
[3]   CT-ASSISTED STEREOTACTIC BRAIN BIOPSY - VALUE OF INTRAOPERATIVE FROZEN SECTION DIAGNOSIS [J].
COLBASSANI, HJ ;
NISHIO, S ;
SWEENEY, KM ;
BAKAY, RAE ;
TAKEI, Y .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (03) :332-341
[5]  
Kleihues P, 1984, Acta Neurochir Suppl (Wien), V33, P171
[6]   APPLICATIONS OF CT-ADAPTED STEREOTAXIS FOR THE DIAGNOSIS AND TREATMENT OF INTRACRANIAL LESIONS [J].
LOBATO, RD ;
RIVAS, JJ .
ACTA NEUROCHIRURGICA, 1987, 87 (1-2) :14-21
[7]   IS PEROPERATIVE SMEAR CYTOLOGY NECESSARY FOR CT-GUIDED STEREOTAXIC BIOPSY [J].
ONEILL, KS ;
DYER, PV ;
BELL, BA ;
WILKINS, PR ;
UTTLEY, D ;
MARSH, HT .
BRITISH JOURNAL OF NEUROSURGERY, 1992, 6 (05) :421-427
[8]  
RAJSHEKHAR V, 1990, British Journal of Neurosurgery, V4, P391, DOI 10.3109/02688699008992761
[9]  
Thomas D G, 1989, Br J Neurosurg, V3, P321, DOI 10.3109/02688698909002810
[10]  
WILD A M, 1990, British Journal of Neurosurgery, V4, P407, DOI 10.3109/02688699008992763