WATER ELECTROLYSIS AND PULSED DIRECT-CURRENT

被引:12
|
作者
SHAABAN, AH
机构
[1] Applied Research Associates Incorporated, Florida 32403-0128, Tyndall Air Force Base
关键词
Electrochemistry; -; Hydrolysis; Water;
D O I
10.1149/1.2220923
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The present study examined the effects of pulsed direct current (dc) on the performance of water electrolysis for hydrogen generation. The laboratory effort consisted of a series of tests using the Fm01-LC electrolytic cell, manufactured by ICI Chemicals and Polymers, and rated at 38 g of H-2/kA . h. Using a 10 weight percent sulfuric acid solution, the electrolytic cell performance was examined using nonpulsed dc, to determine the cells base-line performance and pulsed dc. The pulsed dc test runs were carried out using a square pulse for seven frequencies, ranging from 10 Hz to 40 kHz, and four duty cycles of 10, 25, 50, and 80%. The hydrogen generation rate was used instead of current in order to facilitate an accurate comparison. For the range of tested parameters, the results demonstrated that the nonpulsed dc operation required the least electrical power.
引用
收藏
页码:2863 / 2867
页数:5
相关论文
共 50 条
  • [1] Modeling of Pulsed Direct-Current Glow Discharge
    杜木
    郑亚茹
    范宇佳
    张楠
    刘成森
    王德真
    Plasma Science and Technology, 2010, (04) : 447 - 451
  • [2] Modeling of Pulsed Direct-Current Glow Discharge
    杜木
    郑亚茹
    范宇佳
    张楠
    刘成森
    王德真
    Plasma Science and Technology, 2010, 12 (04) : 447 - 451
  • [3] Modeling of Pulsed Direct-Current Glow Discharge
    Du Mu
    Zheng Yaru
    Fan Yujia
    Zhang Nan
    Liu Chengsen
    Wang Dezhen
    PLASMA SCIENCE & TECHNOLOGY, 2010, 12 (04) : 547 - 551
  • [4] EFFECTS OF CONTINUOUS AND PULSED DIRECT-CURRENT ON DENTIN FORMATION
    WATERS, R
    LAKE, F
    JOURNAL OF DENTAL RESEARCH, 1986, 65 : 188 - 188
  • [5] DIRECT-CURRENT INJURY FROM EXTERNAL PACEMAKER RESULTS IN TISSUE ELECTROLYSIS
    GROSSI, EA
    ANNALS OF THORACIC SURGERY, 1994, 57 (04): : 1053 - 1053
  • [6] DIRECT-CURRENT INJURY FROM EXTERNAL PACEMAKER RESULTS IN TISSUE ELECTROLYSIS
    GROSSI, EA
    PARISH, MA
    KRALIK, MR
    GLASSMAN, LR
    ESPOSITO, RA
    RIBAKOVE, GH
    GALLOWAY, AC
    COLVIN, SB
    ANNALS OF THORACIC SURGERY, 1993, 56 (01): : 156 - 157
  • [7] PULSED DIRECT-CURRENT IONTOPHORESIS AS A NEW METHOD IN THE TREATMENT OF HYPERHIDROSIS
    REINAUER, S
    NEUSSER, A
    SCHAUF, G
    HOLZLE, E
    HAUTARZT, 1995, 46 (08): : 543 - 547
  • [8] EFFECT OF HIGH-TEMPERATURE DIRECT-CURRENT ELECTROLYSIS ON PROPERTIES OF HYDROUS ALUMINOSILICATES
    MACKENZIE, KJ
    JOURNAL OF APPLIED CHEMISTRY, 1970, 20 (03): : 80 - +
  • [9] THE EFFECT OF HIGH-VOLTAGE PULSED DIRECT-CURRENT ON MICROVESSEL PERMEABILITY
    REED, BV
    PHYSICAL THERAPY, 1987, 67 (05): : 765 - 765
  • [10] PULSED DIRECT-CURRENT REDUCES MICROVESSEL PERMEABILITY TO PLASMA-PROTEINS
    REED, B