ERRORS OF FOURIER CHEMICAL-SHIFT IMAGING AND THEIR CORRECTIONS

被引:29
|
作者
WANG, Z
BOLINGER, L
SUBRAMANIAN, VH
LEIGH, JS
机构
[1] Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia
关键词
D O I
10.1016/0022-2364(91)90247-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
From a finite and discrete Fourier transform point of view, we discuss the sources of localization errors in Fourier chemical-shift imaging, and demonstrate them explicitly by computer simulations for simple cases. Errors arise from intravoxel dephasing and the intravoxel asymmetry. The spectral leakage due to intravoxel dephasing is roughly 6-8% from one voxel to one of its nearest neighbors. Neighbors further away are influenced less significantly. The loss of localization due to intravoxel asymmetry effect is also severe. Fortunately, these errors can be corrected under certain conditions. The method for correcting the errors by postprocessing the data is described. © 1991.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 50 条
  • [1] CHEMICAL-SHIFT IMAGING
    GUILFOYLE, DN
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (05) : 479 - 489
  • [2] CHEMICAL-SHIFT IMAGING BY SPIN-ECHO MODIFIED FOURIER METHOD
    SATOH, K
    KOSE, K
    INOUYE, T
    YASUOKA, H
    JOURNAL OF APPLIED PHYSICS, 1985, 57 (06) : 2174 - 2181
  • [3] PROTON CHEMICAL-SHIFT IMAGING
    ZIMMERMANN, BH
    LOEFFLER, W
    FAUL, DD
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (1-2) : 20 - 24
  • [4] CHEMICAL-SHIFT IMAGING - A REVIEW
    BRATEMAN, L
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (05) : 971 - 980
  • [5] NARROWBAND CHEMICAL-SHIFT IMAGING
    FEIG, E
    GREENLEAF, F
    APPLIED OPTICS, 1985, 24 (23): : 3977 - 3984
  • [6] NMR CHEMICAL-SHIFT IMAGING
    BRINK, HF
    BUSCHMANN, MD
    ROSEN, BR
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (01) : 93 - 104
  • [7] A METHOD FOR CHEMICAL-SHIFT IMAGING - DEMONSTRATION OF BONE-MARROW INVOLVEMENT WITH PROTON CHEMICAL-SHIFT IMAGING
    SEPPONEN, RE
    SIPPONEN, JT
    TANTTU, JI
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 585 - 587
  • [8] TAILORED ACQUISITION IN CHEMICAL-SHIFT IMAGING
    HODGKINSON, P
    KEMPHARPER, RO
    HORE, PJ
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 105 (03): : 256 - 259
  • [9] MULTILINE CHEMICAL-SHIFT (MULCH) IMAGING
    JOHNSON, G
    TOFTS, PS
    MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (01) : 107 - 115
  • [10] CHEMICAL-SHIFT IMAGING OF THORACIC MASSES
    ECKEL, CG
    NEWELL, JD
    DELL, LA
    EISENBERG, B
    GRIFFEY, RH
    TRYHUS, MR
    ORRISON, WW