RED-BLOOD-CELL MOTION AND HEMATOCRIT DISTRIBUTION IN A DEFORMING CAPILLARY

被引:3
|
作者
FRIEND, M
LEE, JS
机构
[1] Department of Biomedical Engineering, University of Virginia, Charlottesville, VA
关键词
D O I
10.1115/1.2891210
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Based on the relation between the red blood cell velocity and the blood velocity of the Fahraeus effect, we analyze the motion of a red blood cell in a deforming capillary to investigate how the ventilatory induced deformation affects the transit of the red blood cell through the pulmonary capillary and changes the hematocrit discharged from the capillary. An analytical solution is also obtained for the case of an infinitesimal deformation. The numerical and analytic solutions demonstrate that the variation in discharge hematocrit is proportional to the change of pulmonary capillary blood volume between the time that the red cell enters and the time that it exits the capillary. We also find that this hematocrit variation could be regarded, in terms of transport, to originate from the mid-section of the capillary. © 1990 by ASME.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [1] ON THE HEMATOCRIT DEPENDENCE OF RED-BLOOD-CELL AGGREGATION
    AGOSTI, R
    DETTORRE, M
    CHERUBINI, P
    CLIVATI, A
    BOZZONI, M
    LONGHINI, E
    CLINICAL HEMORHEOLOGY, 1987, 7 (03): : 472 - 472
  • [2] DISTRIBUTION OF PULMONARY CAPILLARY RED-BLOOD-CELL TRANSIT TIMES
    PRESSON, RG
    GRAHAM, JA
    HANGER, CC
    GODBEY, PS
    GEBB, SA
    SIDNER, RA
    GLENNY, RW
    WAGNER, WW
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (02) : 382 - 388
  • [3] INTRALUMINAL DISTRIBUTION OF HEMATOCRIT AND RED-BLOOD-CELL VELOCITY IN THE HAMSTER RETRACTOR MUSCLE
    ELLSWORTH, ML
    PITTMAN, RN
    MICROVASCULAR RESEARCH, 1984, 27 (02) : 241 - 241
  • [4] DIFFERENTIAL VIDEO PHOTOMETER FOR IMPROVED CAPILLARY RED-BLOOD-CELL HEMATOCRIT, VELOCITY, AND FLUX MEASUREMENT
    TOMPKINS, WR
    MIRHASHEMI, S
    INTAGLIETTA, M
    FEDERATION PROCEEDINGS, 1987, 46 (04) : 1543 - 1543
  • [5] RED-BLOOD-CELL MECHANICS AND CAPILLARY BLOOD RHEOLOGY
    SECOMB, TW
    CELL BIOPHYSICS, 1991, 18 (03): : 231 - 251
  • [6] A CAPILLARY RED-BLOOD-CELL VIDEO FLUXMETER
    TOMPKINS, WR
    MIRHASHEMI, S
    INTAGLIETTA, M
    FEDERATION PROCEEDINGS, 1986, 45 (04) : 1154 - 1154
  • [7] PERFUSED CAPILLARY DENSITY, CAPILLARY HEMATOCRIT AND RED-BLOOD-CELL VELOCITY IN THE CEREBRAL-CORTEX OF CAT - INTRAVITAL MICROSCOPIC STUDY
    YAMAKAWA, T
    NIIMI, H
    SUGIYAMA, I
    YAMAGUCHI, S
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 269 - 269
  • [8] RED-BLOOD-CELL FLOW AT CONVERGING CAPILLARY BIFURCATIONS
    WELLS, SM
    POTTER, RF
    SAINANI, DR
    ELLIS, CG
    FASEB JOURNAL, 1992, 6 (05): : A2088 - A2088
  • [9] MEASURING DEVICE FOR RED-BLOOD-CELL FLOW VELOCITY AND HEMATOCRIT IN CAPILLARIES
    COMES, K
    HENRICH, H
    MICROVASCULAR RESEARCH, 1983, 26 (02) : 272 - 272
  • [10] CAPILLARY RED-BLOOD-CELL FLOW - IS IT CHAOS OR IS IT NOISE
    SAINANI, DR
    ELLIS, CG
    LOOKMAN, T
    FASEB JOURNAL, 1993, 7 (04): : A900 - A900