A CALIBRATION SYSTEM FOR SUPERCONDUCTING GRAVIMETERS

被引:24
|
作者
ACHILLI, V
BALDI, P
CASULA, G
ERRANI, M
FOCARDI, S
GUERZONI, M
PALMONARI, F
RAGUNI, G
机构
[1] UNIV BOLOGNA,DIPARTIMENTO FIS SETTORE GEOFIS,I-40126 BOLOGNA,ITALY
[2] UNIV BOLOGNA,IST TOPOG,BOLOGNA,ITALY
[3] IST NAZL GEOFIS,I-00161 ROME,ITALY
[4] IST NAZL GEOFIS,BOLOGNA,ITALY
来源
BULLETIN GEODESIQUE | 1995年 / 69卷 / 02期
关键词
D O I
10.1007/BF00819553
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A new method for the calibration of a superconducting gravity meter is described, in which a 273 Kg annular mass is placed around the meter and is moved up and down. The geometry of the apparatus is easy to model and the accuracy in the computation of the gravity variation induced by the mass, 6.7 mu gal, is limited only by the accuracy in the knowledge of value of the gravitational constant. Measurements done in '98 and '92 for the calibration of the instrument GWR-T015 are described. The calibration factor has been determined with a precision of about 0.3%.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [1] The Frankfurt calibration system for relative gravimeters
    Richter, B
    Wilmes, H
    Nowak, I
    METROLOGIA, 1995, 32 (03) : 217 - 223
  • [2] On the Potential of Least Squares Response Method for the Calibration of Superconducting Gravimeters
    Abd El-Gelil, Mahmoud
    Pagiatakis, Spiros
    El-Rabbany, Ahmed
    INTERNATIONAL JOURNAL OF GEOPHYSICS, 2012, 2012
  • [3] Optimized strategy for the calibration of superconducting gravimeters at the one per mille level
    Van Camp, Michel
    Meurers, Bruno
    de Viron, Olivier
    Forbriger, Thomas
    JOURNAL OF GEODESY, 2016, 90 (01) : 91 - 99
  • [4] Optimized strategy for the calibration of superconducting gravimeters at the one per mille level
    Michel Van Camp
    Bruno Meurers
    Olivier de Viron
    Thomas Forbriger
    Journal of Geodesy, 2016, 90 : 91 - 99
  • [5] On the Accuracy of the Calibration of Superconducting Gravimeters Using Absolute and Spring Sensors: a Critical Comparison
    Umberto Riccardi
    Severine Rosat
    Jacques Hinderer
    Pure and Applied Geophysics, 2012, 169 : 1343 - 1356
  • [6] On the Accuracy of the Calibration of Superconducting Gravimeters Using Absolute and Spring Sensors: a Critical Comparison
    Riccardi, Umberto
    Rosat, Severine
    Hinderer, Jacques
    PURE AND APPLIED GEOPHYSICS, 2012, 169 (08) : 1343 - 1356
  • [7] Evaluation of the precision of using absolute gravimeters to calibrate superconducting gravimeters
    Francis, O
    van Dam, T
    METROLOGIA, 2002, 39 (05) : 485 - 488
  • [8] Calibration of gravimeters with the VRR 8601 calibration platform
    VanRuymbeke, M
    Somerhausen, A
    Grammatica, N
    METROLOGIA, 1995, 32 (03) : 209 - 216
  • [9] Testing gravitational physics with superconducting gravimeters
    Shiomi, Sachie
    PROGRESS OF THEORETICAL PHYSICS SUPPLEMENT, 2008, (172): : 61 - 70
  • [10] Tilt effects on GWR superconducting gravimeters
    Riccardi, U.
    Hinderer, J.
    Boy, J. -P.
    Rogister, Y.
    JOURNAL OF GEODYNAMICS, 2009, 48 (3-5) : 316 - 324