INFECTED ENDOCARDIAL PACEMAKER ELECTRODES - SUCCESSFUL OPEN INTRACARDIAC REMOVAL

被引:14
|
作者
NIEDERHAUSER, U
VONSEGESSER, LK
CARREL, TP
LASKE, A
BAUER, E
SCHONBECK, M
TURINA, M
机构
[1] Clinic for Gardiovascular Surgery, University Hospital, Zurich
来源
关键词
PACEMAKER ELECTRODE; INFECTION; ELECTRODE EXPLANTATION; CARDIOPULMONARY BYPASS;
D O I
10.1111/j.1540-8159.1993.tb01581.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The long-term results after open intracardiac removal of infected pacing electrodes are presented. Methods: between 1985 and 1990 open intracardiac removal of 19 infected pacing electrodes was performed in seven patients (six male and one female), with a mean age of 56 years. The indications were: persisting bacteremia in three; generator pocket infection in four; endocarditis in one; and ventricular tachycardia caused by retracted electrodes in one. All electrodes were fixed in the right heart and extraction by closed methods failed. Percutaneous catheter techniques were not applied in these seven patients. In five patients two ventricular electrodes had to be removed, and in two patients a single one. A total of seven atrial electrodes were removed in six patients (one electrode each in five patients; two electrodes in one patient). All atrial and two ventricular electrodes could be removed through a pursestring suture without use of a pump oxygenator. For the removal of ten ventricular electrodes in six patients (two electrodes each in four patients; 1 electrode each in two patients) a right-sided atriotomy was necessary with cardiopulmonary bypass (CPB). Simultaneously, five new pacing systems were implanted. Results: there were no early or late mortalities. In january 1991, all seven patients are alive and in a mean New York Heart Association Class 1,3 of heart failure after a mean interval of 33 months. In all cases the infection could be controlled with a simultaneous antimicrobial chemotherapy and the postoperative period was free of major complications. Conclusion: open intracardiac removal of retained pacing electrodes with or without use of CPB is a safe procedure without major complications. It is mandatory for all infected pacing electrodes that cannot be extracted by closed methods.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [1] Giant vegetation on permanent endocavitary pacemaker lead and successful open intracardiac removal
    Gurbuz, Ali
    Yesil, Murat
    Yetkin, Ufuk
    Postaci, Nursen
    Yurekli, Ismail
    Arikan, Erdinc
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2009, 9 (03): : 249 - 251
  • [2] RETAINED ENDOCARDIAL PACEMAKER ELECTRODES
    FURMAN, S
    ESCHER, DJW
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 55 (05): : 737 - &
  • [3] SURGICAL-TREATMENT OF INTRACARDIAC INFECTED PACEMAKER ELECTRODES AND CATHETER REMNANTS
    SCHULER, S
    HETZER, R
    STEGMANN, T
    BORST, HG
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 (03): : 151 - 155
  • [4] CARDIAC PERFORATION BY ENDOCARDIAL PACEMAKER ELECTRODES - CLINICAL EVALUATION WITH SPECIAL REFERENCE TO ROLE OF INTRACARDIAC ELECTROGRAPHY
    VERA, Z
    MASON, DT
    AWAN, NA
    JANZEN, D
    MCMILLIN, D
    MOKHTAR, S
    DETJE, RL
    IKEDA, R
    CLINICAL RESEARCH, 1976, 24 (03): : A244 - A244
  • [5] REMOVAL OF INFECTED ENTRAPPED PACEMAKER ELECTRODES BY CONTINUOUS TRACTION
    SCHMIDT, G
    WIRTZFELD, A
    HIMMLER, FC
    KLEIN, G
    ALT, E
    SEIDL, KF
    PRAUER, HW
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1980, 105 (46) : 1609 - 1614
  • [6] PACEMAKER TREATMENT .3. ENDOCARDIAL ELECTRODES IN TEMPORARY PACEMAKER TREATMENT
    LETH, A
    MEIBOM, J
    HAGHFELT, T
    HANSEN, JF
    DANISH MEDICAL BULLETIN, 1974, 21 (04): : 139 - 144
  • [7] Removal of a chronically infected bipolar pacemaker electrode - A successful case report
    Tsukamoto, S
    Shindo, S
    Niino, T
    Yoshitake, I
    Akiyama, K
    Shiono, M
    Negishi, N
    Sezai, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (06): : 452 - 454
  • [8] Video-assisted endoscopic removal of infected endocardial pacemaker lead with large floating vegetation
    Chu, JJ
    Lin, PJ
    Chang, CH
    Wang, CC
    Tan, PPC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (11): : 1700 - 1703
  • [9] ANODAL AND CATHODAL STIMULATION THRESHOLDS OF ENDOCARDIAL PACEMAKER ELECTRODES
    PARKER, B
    FURMAN, S
    MEHRA, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A100 - A100
  • [10] MALPLACEMENT OF ENDOCARDIAL PACEMAKER ELECTRODES IN MIDDLE CARDIAC VEIN
    KEMP, A
    JOHANSEN, JK
    KJAERGAARD, E
    ACTA MEDICA SCANDINAVICA, 1976, 199 (1-2): : 7 - 11