FEASIBILITY OF LONG-TERM ELECTROCARDIOGRAPHIC MONITORING WITH AN IMPLANTED DEVICE FOR SYNCOPE DIAGNOSIS

被引:16
|
作者
MURDOCK, CJ [1 ]
KLEIN, GJ [1 ]
YEE, R [1 ]
LEITCH, JW [1 ]
TEO, WS [1 ]
NORRIS, C [1 ]
机构
[1] UNIV WESTERN ONTARIO HOSP,ARRHYTHMIA SERV,CARDIAC INVEST UNIT,POB 5339,POSTAL STN A,LONDON N6A 5A5,ONTARIO,CANADA
来源
关键词
cardiac pacing; syncope;
D O I
10.1111/j.1540-8159.1990.tb04011.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patients with infrequent recurrent syncope undiagnosed after extensive noninvasive and invasive testing pose a diagnostic and therapeutic dilemma. The purpose of this pilot study was to assess the feasibility of using an implanted, long‐term monitor as an aid to diagnosis in these patients. This was done using commercially available pacemakers with monitoring functions. Sixteen patients (eight males and eight femaiesj, aged 59.7 ± 17 years who had unexplained syncope despite a 12‐lead electrocardiogram, repeated Holter monitoring, exercise testing, echocardiography, an eJectro‐physioJogical study, and a tiJf test (n = 6), were entered into the study. Patients had experienced a mean of 3.3 ± 1 episodes of syncope in the 12 months prior to the study. All provided a history suggestive of Stokes‐Adams attacks and were referred for consideration of pacemaker implantation. Two patients had ischemic heart disease and one patient had a long QT interval. Patients had an Intermedics Nova II or Medtronic Quintech DPG pulse generator capable of recording sensed and paced events implanted with a single right ventricular lead. Syncope or presyncope occurred in ten patients (62%) 4.9 ± 4.2 months after pacemaker implantation. Bradycardia was detected in six patients and four patients had no arrhythmia. In addition to bradycardia, one patient also had tachycardia detected. Pacing therapy resulted in symptom relief in all six patients with syncope or presyncope due to bradycardia. Complications of pacemaker implantation (lead insulation failure) occurred in two patients. One of these patients subsequently had an infection of the generator pocket with associated systemic sepsis. Although the devices used in this study have serious limitations, the results suggest that continuous long‐term electrocardiographic monitoring can be useful in patients with recurrent syncope and a negative diagnostic work‐up. A smaller device with self‐contained electrodes designed for this purpose would be required for wider applicability. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:1374 / 1378
页数:5
相关论文
共 50 条
  • [1] Asystole during long-term electrocardiographic monitoring in children with unexplained syncope
    Shkolnikova, M.
    Polyakova, E.
    Vakhmistrova, T.
    Termosesov, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 300 - 300
  • [2] Long-term patient acceptance of and satisfaction with implanted device remote monitoring
    Ricci, Renato Pietro
    Morichelli, Loredana
    Quarta, Laura
    Sassi, Anna
    Porfili, Antonio
    Laudadio, Maria Teresa
    Gargaro, Alessio
    Santini, Massimo
    EUROPACE, 2010, 12 (05): : 674 - 679
  • [3] LONG-TERM MONITORING OF PATIENTS WITH IMPLANTED PACEMAKERS
    DREIFUS, LS
    OHM, OJ
    PENNOCK, RS
    MORSE, D
    FELDMAN, M
    ZINBERG, A
    HEART & LUNG, 1982, 11 (05): : 417 - 421
  • [4] Long-term skin hyperpigmentation after electrocardiographic monitoring
    Sprung, J
    Schoenwald, PK
    JOURNAL OF CLINICAL ANESTHESIA, 1997, 9 (07) : 602 - 603
  • [5] PERSPECTIVES ON LONG-TERM ELECTROCARDIOGRAPHIC RECORDING AND MONITORING - DISCUSSION
    BIGGER, JT
    CIRCULATION, 1987, 75 (04) : 58 - 59
  • [6] Feasibility of Long-Term Daily Life Electrocardiogram Monitoring Based on a Wearable Armband Device
    Lazaro, Jesus
    Reljin, Natasa
    Noh, Yeonsik
    Laguna, Pablo
    Chon, Ki H.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4314 - 4317
  • [7] LONG-TERM ELECTROCARDIOGRAPHIC MONITORING IN PATIENTS WITH THE IDIOPATHIC LONG QT SYNDROME
    OSTERHUES, HH
    EGGELING, T
    HOHER, M
    KOCHS, M
    HOMBACH, V
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1993, 118 (44) : 1589 - 1593
  • [8] Long-term patient satisfaction with implanted device remote monitoring: a comparison among different systems
    Artico, Jessica
    Zecchin, Massimo
    Fantasia, Anna Zorzin
    Skerl, Giulia
    Ortis, Benedetta
    Franco, Stefania
    Albani, Stefano
    Barbati, Giulia
    Cristallini, Jacopo
    Cannata', Antonio
    Sinagra, Gianfranco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (08) : 542 - 550
  • [9] Feasibility of a Long-Term Implanted Continuous Glucose Monitor (CGM)
    Butler, Anthony
    Robinson, Lesley
    Obeyesekere, Varuni R.
    Jones, Hannah
    Kong, Yee W.
    Yuan, Cheng Yi
    Bertsch, Krista
    Routh, Timothy L.
    Martha, Sandra L.
    Tan, Jason
    O'Neal, David N.
    DIABETES, 2023, 72
  • [10] Clinical characteristics associated with bradycardia and asystole in patients with syncope undergoing long-term electrocardiographic monitoring with implantable loop recorder
    Peter Mitro
    Miloš Šimurda
    Ervin Müller
    Wiener klinische Wochenschrift, 2017, 129 : 451 - 457