THE EFFECTIVE LENGTH OF A FLAT-PLATE HEAT-PIPE COVERED PARTIALLY BY A STRIP HEATER ON THE EVAPORATOR SECTION

被引:6
|
作者
SUN, KH [1 ]
LIU, CY [1 ]
LEONG, KC [1 ]
机构
[1] NANYANG TECHNOL UNIV,SCH MECH & PROD ENGN,SINGAPORE 2263,SINGAPORE
来源
HEAT RECOVERY SYSTEMS & CHP | 1995年 / 15卷 / 04期
关键词
D O I
10.1016/0890-4332(95)90007-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
An approximate method is presented for calculating the effective length of a flat plate heat pipe when a strip heater is partially covering the evaporator section. For a specific width of the strip heater, the optimal position to achieve a minimum effective length is found when the heater is placed symmetrically at the centre of the evaporator section. In this position, a higher value of the capillary heat transport limit can be achieved as compared to the case where the heater is placed on one side of the evaporator section.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 50 条
  • [1] THERMAL PERFORMANCE OF A FLAT-PLATE HEAT-PIPE COLLECTOR ARRAY
    BONG, TY
    NG, KC
    BAO, H
    SOLAR ENERGY, 1993, 50 (06) : 491 - 498
  • [2] EXPERIMENTAL INVESTIGATION OF A FLAT-PLATE OSCILLATING HEAT PIPE WITH MODIFIED EVAPORATOR AND CONDENSER
    Rhodes, M. J.
    Taylor, M. R.
    Monroe, J. G.
    Thompson, S. M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 8A, 2015,
  • [3] Visualization and evaporator resistance measurement for a groove-wicked flat-plate heat pipe
    Wong, Shwin-Chung
    Chen, Chung-Wei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (9-10) : 2229 - 2234
  • [4] Numerical and experimental investigation of flat-plate pulsating heat pipes with extra branches in the evaporator section
    Sedighi, Erfan
    Amarloo, Ali
    Shafii, Behshad
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 431 - 441
  • [5] VAPOR FLOW CALCULATIONS IN A FLAT-PLATE HEAT PIPE
    VANOOIJEN, H
    HOOGENDOORN, CJ
    AIAA JOURNAL, 1979, 17 (11) : 1251 - 1259
  • [6] Flat plate loop heat pipe with a novel evaporator structure
    Tsai, MC
    Yu, CS
    Kang, SW
    TWENTY-FIRST ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2005, 2005, : 187 - 190
  • [7] Effect of evaporation section and condensation section length on thermal performance of flat plate heat pipe
    Wang, Shuangfeng
    Chen, Jinjian
    Hu, Yanxin
    Zhang, Wei
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2367 - 2373
  • [8] An R1234ze(E) loop heat pipe with flat-plate evaporator for cooling electronic devices
    Zhao, S. C.
    Zhang, Zikang
    Zhao, Runze
    Wu, Tong
    Zhang, Xiaoyu
    Liu, Z. C.
    Liu, Wei
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 42
  • [9] Fluid flow and heat transfer in flat-plate oscillating heat pipe
    Liu, Xiangdong
    Chen, Yongping
    ENERGY AND BUILDINGS, 2014, 75 : 29 - 42
  • [10] STUDY OF EHD HEAT PIPE .2. EXPERIMENT OF FLAT-PLATE HEAT PIPE
    KIKUCHI, K
    JOURNAL OF MECHANICAL ENGINEERING LABORATORY, 1979, 33 (04): : 198 - 208