MEASUREMENT AND MODELING OF OPERATIONAL-AMPLIFIER POWER-SUPPLY REJECTION

被引:6
|
作者
BRINSON, ME [1 ]
FAULKNER, DJ [1 ]
机构
[1] UNIV N LONDON,SCH ELECTR & COMMUN ENGN & APPL PHYS,LONDON N7 8DB,ENGLAND
关键词
D O I
10.1080/00207219508926200
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new approach to the measurement of operational amplifier power supply rejection, based on the measurement of the power supply injected signal gain of a high-gain differential amplifier configuration, is presented. Measured results for 741 and pin-compatible operational amplifiers are tabulated. A new SPICE macromodel which models operational amplifier power supply rejection characteristics is described. Design equations are provided to extract macromodel parameters from manufacturer's data sheets or measured power supply rejection data. Good agreement has been found between measured operational amplifier power supply rejection characteristics and simulated circuit performance based on the new macromodel.
引用
收藏
页码:667 / 678
页数:12
相关论文