DOES PULSED-DOPPLER ULTRASOUND HAVE MUTAGENIC EFFECTS - APPLICATION OF THE AMES MUTAGENICITY ASSAY TO TEST PULSED-DOPPLER EQUIPMENT

被引:1
|
作者
MEYENBURG, M
LANG, R
SALING, E
WEGNER, RD
机构
[1] Institute of Perinatal Medicine, Free University, Berlin
[2] Institute of Human Genetics, Free University, Berlin
[3] Department of Experimental Toxicology, Schering Ag, Berlin
关键词
bioeffects; mutagenic effects; pulsed Doppler;
D O I
10.1111/j.1540-8175.1990.tb00417.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of fetal blood flow has been accepted using pulsed‐Doppler ultrasound. Until recently, there has been a lack of investigations concerning the potential risks of this method. The possible mutagenic effect of a pulsed‐Doppler system was examined in vitro by applying the Ames test. Tester strains of Salmonella typhimurium indicating point mutations were irradiated (TA 98, TA 100, TA 102, TA 1535, TA 1537, TA 1538). A commercially available duplex system was applied in the experiments emitting an ultrasound beam with a spatial‐peak temporal‐average of 5.2 mW/cm2 and a spatial‐peak temporal‐peak of 117 mW/cm2 at a frequency of 2 MHz. The tester strains were sonicated up to 60 minutes, the bacterial suspension being in direct contact with the transducer surface. The ultrasound‐exposed bacterial suspensions were compared with nonexposed samples. Reference mutagens were used for checking the sensitivity of the system. The results do not indicate any mutagenic effects. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:657 / 660
页数:4
相关论文
共 50 条
  • [1] PULSED-DOPPLER ECHOCARDIOGRAPHY
    THOMSON, FJ
    NEW ZEALAND MEDICAL JOURNAL, 1979, 90 (649) : 479 - 479
  • [2] IS ROUTINE PULSED-DOPPLER ECHOCARDIOGRAPHY ACCURATE
    REED, GL
    KING, ME
    JIANG, L
    WEYMAN, AE
    CIRCULATION, 1986, 74 (04) : 180 - 180
  • [3] ASSESSMENT OF MYOCARDIAL-CONTRACTILITY IN DOGS USING PULSED-DOPPLER ULTRASOUND
    ALVERSON, DC
    BLOMQUIST, T
    ELDRIDGE, MW
    BERMAN, W
    JOURNAL OF CARDIOVASCULAR ULTRASONOGRAPHY, 1987, 6 (02): : 77 - 83
  • [4] Volumetric flow estimation in vivo and in vitro using pulsed-Doppler ultrasound
    Holland, CK
    Clancy, MJ
    Taylor, KJW
    Alderman, JL
    Purushothaman, K
    McCauley, TR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05): : 591 - 603
  • [5] DIAGNOSIS OF GIANT VARIX OF THE CORONARY VEIN BY PULSED-DOPPLER SONOGRAPHY
    HUEY, H
    COOPERBERG, PL
    BOGOCH, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (01) : 77 - 78
  • [6] VALUE OF PULSED-DOPPLER STUDIES IN RENAL-TRANSPLANTATION RECIPIENTS
    ARGYROPOULOU, M
    BRUNELLE, F
    ANNALES DE PEDIATRIE, 1990, 37 (02): : 117 - 119
  • [7] TWO-DIMENSIONAL AND PULSED-DOPPLER ECHOCARDIOGRAPHIC IMAGING OF CARDIAC PSEUDOANEURYSM
    TURGEMAN, Y
    ROSENFELD, T
    MERIN, G
    LEWIS, BS
    JOURNAL OF CARDIOVASCULAR ULTRASONOGRAPHY, 1987, 6 (03): : 183 - 185
  • [8] The influence of acoustic impedance mismatch on poststenotic pulsed-Doppler ultrasound measurements in a coronary artery model
    Jones, SA
    Leclerc, H
    Chatzimavroudis, GP
    Kim, YH
    Scott, NA
    Yoganathan, AP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (05): : 623 - 634
  • [9] DERIVATION OF VESSEL DIAMETER FROM ANALYSIS OF PULSED-DOPPLER SPECTRUMS INVITRO
    HAYES, J
    MICCO, A
    DIETRICH, B
    MOORE, L
    ZAMUDIO, S
    CLINICAL RESEARCH, 1992, 40 (01): : A44 - A44
  • [10] DUAL TRANSDUCER PULSED-DOPPLER ULTRASOUND (DTP-DU) AND ITS APPLICATION IN MEASURING THE DOPPLER ANGLE AND BLOOD-FLOW VELOCITY
    ASHRAFZADEH, A
    CHEUNG, J
    BEDFORD, T
    DORMER, K
    FEDERATION PROCEEDINGS, 1985, 44 (05) : 1565 - 1565