CIRCLE OF WILLIS - EVALUATION WITH SPIRAL CT ANGIOGRAPHY, MR-ANGIOGRAPHY, AND CONVENTIONAL ANGIOGRAPHY

被引:137
|
作者
KATZ, DA
MARKS, MP
NAPEL, SA
BRACCI, PM
ROBERTS, SL
机构
[1] Department of Radiology, Stanford University Medical Center, Stanford, CA 94305-5105
关键词
CEREBRAL BLOOD VESSELS; COMPUTED TOMOGRAPHY (CT); HELICAL; MAGNETIC RESONANCE (MR); VASCULAR STUDIES;
D O I
10.1148/radiology.195.2.7724764
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the use of spiral computed tomographic (CT) angiography in the analysis of the arteries of the circle of Willis and compare these results with magnetic resonance (MR) angiography and conventional angiography. MATERIALS AND METHODS: The results in 17 patients who underwent examination were prospectively studied in a blinded fashion. The presence or absence of the arteries of the circle of Willis was determined by using maximum intensity projection reconstructions from CT angiography and MR angiography. These results were compared with results from conventional angiography. RESULTS: Similar sensitivities were determined for CT angiography (88.5%) and MR angiography (85.5%); however, MR angiography was found to differ significantly (P = .005) from conventional angiography. No significant differences (P > .05) were found between the two modalities and conventional angiography in the detection of the anterior, middle, or posterior cerebral arteries or the anterior communicating artery. CONCLUSION: Spiral CT angiography is highly sensitive in the detection of arterial anatomy in the circle of Willis and is a reliable alternative to MR angiography.
引用
收藏
页码:445 / 449
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY
    SCHWARTZ, RB
    TICE, HM
    HOOTEN, SM
    HSU, LG
    STIEG, PE
    RADIOLOGY, 1994, 192 (03) : 717 - 722
  • [2] CT angiography of the circle of Willis: Is spiral technology always necessary?
    Brown, JH
    Lustrin, ES
    Lev, MH
    Taveras, JM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (09) : 1794 - 1796
  • [3] Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography
    Stock, KW
    Wetzel, S
    Kirsch, E
    Bongartz, G
    Steinbrich, W
    Radue, EW
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (08) : 1495 - 1499
  • [4] SPIRAL CT ANGIOGRAPHY - AN ALTERNATIVE TO CONVENTIONAL ANGIOGRAPHY
    BLUEMKE, DA
    CHAMBERS, TP
    RADIOLOGY, 1995, 195 (02) : 317 - 319
  • [5] Evaluation of circle of Willis aneurysms with spiral computed tomographic angiography
    Pavcec, Zlatko
    Zokalj, Ivan
    Saghir, Hussein
    Pal, Andrej
    Ozretic, David
    Podoreski, Dijana
    COLLEGIUM ANTROPOLOGICUM, 2006, 30 (04) : 867 - 870
  • [6] ANGIOGRAPHY ON CT IN RELATION TO THE CIRCLE OF WILLIS
    BIJLSMA, P
    COBBEN, JJ
    DIAGNOSTIC IMAGING, 1982, 51 (06) : 319 - 319
  • [7] CT angiography of the circle of Willis: Is spiral technology always necessary? Comment
    Marks, MP
    Rubin, GD
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (09) : 1796 - 1797
  • [8] MR-ANGIOGRAPHY
    SEIDERER, M
    RECENT ADVANCES IN INTERVENTIONAL RADIOLOGY AND NEW VASCULAR IMAGING, 1989, 813 : 101 - 110
  • [9] FEMORAL MR-ANGIOGRAPHY VERSUS CONVENTIONAL ANGIOGRAPHY - PRELIMINARY-RESULTS
    QUINN, SF
    DEMLOW, TA
    HALLIN, RW
    EIDEMILLER, LR
    SZUMOWSKI, J
    RADIOLOGY, 1993, 189 (01) : 181 - 184
  • [10] HEMODYNAMICS AND ANATOMY OF THE CIRCLE OF WILLIS-TECHNIQUE AND CLINICAL RANKING OF SELECTIVE MR-ANGIOGRAPHY
    FURST, G
    SITZER, M
    FISCHER, H
    HOFER, M
    STEINMETZ, H
    AULICH, A
    KAHN, T
    MODDER, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (06): : 499 - 505