Monte Carlo simulations of a powder diffractometer installed on a long pulse target station using wavelength frame multiplication

被引:13
|
作者
Lieutenant, K. [1 ,2 ]
Mezei, F. [1 ,3 ]
机构
[1] Hahn Meitner Inst Berlin GmbH, Glienicker St 100, D-14109 Berlin, Germany
[2] Inst Laue Langevin, F-38042 Grenoble, France
[3] LANSCE, Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
MC simulations; Pulsed neutron source; Diffractometer; Frame multiplication; Beam extraction system; Ballistic guide;
D O I
10.1080/10238160600766401
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
MC simulations of neutron diffractometer have been performed using the VITESS software package to check the feasibility of the frame multiplication concept and to compare a powder instrument installed on a long pulse target station (LPTS) with an equivalent instrument installed on a decoupled poisoned moderator of a short pulse target station (SPTS) of the same power. The simulations show that frame multiplication can be realised, if five choppers are used to determine the frame. For the same FWHM peak width, the LPTS yields comparable peak intensities for wavelengths of about 1 angstrom, much higher intensities than the SPTS for long wavelengths, and a quite symmetric peak shape for all wavelengths. Therefore, a combination of high-energy LPTS and pulse shaping choppers can be used instead of a decoupled poisoned moderator of a SPTS to run a TOF powder diffractometer. It is the better choice (than the SPTS solution), because it matches the performance of SPTS in the case most favourable for SPTS: highest resolution offered by the poisoned moderator, has the capability of easily increasing the intensity by its variable resolution and gives superior intensity for longer neutron wavelengths.
引用
收藏
页码:177 / 191
页数:15
相关论文
共 27 条
  • [1] Design of a Neutron Diffractometer at SINQ Using Monte Carlo Simulations
    Keller, Lukas
    Filges, Uwe
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C143 - C143
  • [2] Optimization of monochromator and ToF powder diffractometers at a long-pulse spallation source using Monte Carlo simulations
    Saroun, J.
    Beran, P.
    JOURNAL OF NEUTRON RESEARCH, 2014, 17 (01) : 53 - 62
  • [3] Monte Carlo simulations of various instrument configurations of the new structure powder diffractometer (SPODI)
    Hoelzel, M.
    Gilles, R.
    Schlapp, M.
    Boysen, H.
    Fuess, H.
    PHYSICA B-CONDENSED MATTER, 2004, 350 (1-3) : E671 - E673
  • [4] Wavelength frame multiplication for reflectometry at long-pulse neutron sources
    Loehmann, Oliver
    Silvi, Luca
    Kadletz, Peter M.
    Vaytet, Neil
    Arnold, Owen
    Jones, Matthew D.
    Nilsson, Jonas
    Hart, Michael
    Richter, Tobias
    von Klitzing, Regine
    Jackson, Andrew J.
    Arnold, Thomas
    Woracek, Robin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [5] Analytical calculations and Monte-Carlo simulations of a high-resolution backscattering spectrometer for the long wavelength target station at the Spallation neutron source
    Bordallo, HN
    Herwig, KW
    Zsigmond, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2): : 216 - 225
  • [6] Monte Carlo modelling of a diffractometer using statistical time modulation to exploit the long pulse structure at the ICONE HiCANS.
    Ott, Frederic
    10TH INTERNATIONAL MEETING OF UNION FOR COMPACT ACCELERATOR-DRIVEN NEUTRON SOURCES, UCANS-10, 2024, 298
  • [7] The precision of lead frame etching characteristics using Monte-Carlo simulations
    Jeong, Heung-Cheol
    Choi, Gyung-Min
    Kim, Duck-Jool
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2007, 8 (01) : 73 - 78
  • [8] Quantifying the determinants of leakage multiplication for large uranium objects using Monte Carlo simulations
    Tweardy, Matthew C.
    McConchie, Seth
    Hayward, Jason P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954 (954):
  • [9] Analysis of Melanin Concentration on Reflective Pulse Oximetry Using Monte Carlo Simulations
    Reiser, Maximilian
    Amft, Oliver
    Breidenassel, Andreas
    IEEE ACCESS, 2025, 13 : 24454 - 24462
  • [10] Long-term behaviour of irradiated hcp Zr using Monte Carlo simulations
    Arévalo, C
    Caturla, MJ
    Perlado, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 228 : 176 - 180