DETERMINATION OF A CEPHALOSPORIN ANTIBIOTIC, CEFTIBUTEN, IN HUMAN PLASMA WITH COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION

被引:12
|
作者
PAN, HT [1 ]
KUMARI, P [1 ]
LIM, J [1 ]
LIN, CC [1 ]
机构
[1] SCHERING PLOUGH CORP,DEPT DRUG METAB,BLOOMFIELD,NJ 07003
关键词
D O I
10.1002/jps.2600810715
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A column-switching high-performance liquid chromatographic assay combined with a heart-cutting technique and UV detection (LC/LC/UV) was developed to determine ceftibuten, a new oral cephalosporin, in human plasma. Plasma samples were directly injected into the first chromatographic column for samples cleanup and extraction. Thereafter, a switching valve, located at the junction of the first cleanup column and the second analytical column, opened during a 4-6-min interval after injection to transfer the segment containing ceftibuten into the analytical column for quantitation. The method was used routinely in pharmacokinetic studies and has the advantages of simplicity, improved sensitivity, and selectivity. Concentrations of ceftibuten in plasma over a range of 0.1-20-mu-g/mL can be determined with high precision and reproducibility. A single, oral, 200-mg dose of ceftibuten in humans resulted in a maximum concentration of 9.79-mu-g/mL, an area under the plot of concentration of drug in plasma versus time (0-12 h) of 47.77-mu-g.h/mL, and a half-life of 3.2 h. These results document the utility of the LC/LC/UV method in clinical pharmacokinetic studies.
引用
收藏
页码:663 / 666
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF CEFODIZIME IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    BOMPADRE, S
    FERRANTE, L
    LEONE, L
    DEMARTINIS, M
    GINALDI, L
    QUAGLINO, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (14): : 2895 - 2909
  • [2] DETERMINATION OF ALFUZOSIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    CARLUCCI, G
    DIGIUSEPPE, E
    MAZZEO, P
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (18): : 3989 - 3997
  • [3] DETERMINATION OF PLASMA ADENOSINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING AND FLUOROMETRIC DETECTION
    NITHIPATIKOM, K
    MIZUMURA, T
    GROSS, GJ
    ANALYTICAL BIOCHEMISTRY, 1994, 223 (02) : 280 - 284
  • [4] DETERMINATION OF OXYTETRACYCLINE IN FISH PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN-SWITCHING
    EIVINDVIK, K
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 3061 - 3071
  • [5] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [6] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230
  • [7] DETERMINATION OF NIFEDIPINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING TECHNIQUE
    HORVAI, G
    HRABECZYPALL, A
    HORVATH, V
    KLEBOVICH, I
    MIKROCHIMICA ACTA, 1994, 113 (3-6) : 171 - 178
  • [8] Determination of the cephalosporin antibiotic cephradine in human plasma by high-performance liquid chromatography with ultraviolet detection
    Johnson, VM
    Allanson, JP
    Causon, RC
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (01): : 71 - 80
  • [9] Automated determination of reboxetine by high-performance liquid chromatography with column-switching and ultraviolet detection
    Härtter, S
    Weigmann, H
    Hiemke, C
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (01): : 135 - 140
  • [10] AUTOMATED-DETERMINATION OF FLUVOXAMINE IN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HARTTER, S
    WETZEL, H
    HIEMKE, C
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2082 - 2086