THE SIGNIFICANCE OF WIPE SAMPLES

被引:0
|
作者
CAPLAN, KJ
机构
来源
关键词
D O I
10.1202/0002-8894(1993)054<0070:TSOWS>2.0.CO;2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A search for any meaningful quantitative correlation between wipe samples and concurrent airborne concentrations of the same contaminant was made. A preliminary literature search revealed little. A questionnaire survey was conducted of the members of the American Industrial Hygiene Association, the American Conference of Government Industrial Hygienists, and the Health Physics Society. Follow-up was conducted for all responses concerning available data and/or literature references. The Health Physics profession has done most of the work in this field. Reported ratios between surface and air concentrations cover a million-fold range, with most of the data showing a thousand-fold range. For Industrial Hygiene purposes, there is no usable quantitative correlation between air and wipe samples. Wipe samples are useful for estimating skin absorption if adequate absorption data is available. Ingestion may also be estimated if consumption of food or drink, or smoking, is permitted in contaminated areas. A basis for using wipe samples in determining whether surfaces are ''as clean as practicable'' is suggested. Surface contamination by infectious biological agents is not included in this discussion.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [1] THE APPLICATION AND SIGNIFICANCE OF WIPE SAMPLES
    KLINGNER, TD
    MCCORKLE, T
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (03): : 251 - 254
  • [2] EFFICIENCY OF TRITIUM WIPE SAMPLES
    GREGORY, WD
    MAILLIE, HD
    HEALTH PHYSICS, 1977, 33 (06): : 665 - 665
  • [3] Collecting Hand Wipe Samples to Assess Thirdhand Smoke Exposure
    Mahabee-Gittens, E. Melinda
    Quintana, Penelope J. E.
    Hoh, Eunha
    Merianos, Ashley L.
    Stone, Lara
    Lopez-Galvez, Nicolas
    Matt, Georg E.
    FRONTIERS IN PUBLIC HEALTH, 2021, 9
  • [4] EFFICIENCY OF WIPE SAMPLES IN DETERMINATION OF C-14 AND TRITIUM CONTAMINATION
    MUSE, LA
    RAO, V
    HEALTH PHYSICS, 1976, 30 (04): : 355 - 356
  • [5] The use of composite dust wipe samples as a means of assessing lead exposure
    Friederich, NJ
    Bauer, KM
    Schultz, BD
    Holderman, TS
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1999, 60 (03): : 326 - 333
  • [6] Discussion of challenges encountered during the collection and submission of wipe/leak test samples
    G. W. Wright
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 351 - 355
  • [7] Application of a fast fluorimetric test for analysis of beryllium surface wipe samples.
    Birnbaum, ER
    McCleskey, TM
    Ehler, DS
    Sully, EK
    Minogue, EM
    Sauer, NN
    Whitney, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U315 - U315
  • [8] Utility of snout wipe samples for influenza A virus surveillance in exhibition swine populations
    Edwards, Jody L.
    Nelson, Sarah W.
    Workman, Jeffrey D.
    Slemons, Richard D.
    Szablewski, Christine M.
    Nolting, Jacqueline M.
    Bowman, Andrew S.
    INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2014, 8 (05) : 574 - 579
  • [9] Discussion of challenges encountered during the collection and submission of wipe/leak test samples
    Wright, GW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (02) : 351 - 355
  • [10] A portable x-ray fluorescence instrument for analyzing dust wipe samples for lead: Evaluation with field samples
    Sterling, DA
    Lewis, RD
    Luke, DA
    Shadel, BN
    ENVIRONMENTAL RESEARCH, 2000, 83 (02) : 174 - 179