HEPARIN-COATED CARDIOPULMONARY BYPASS CIRCUITS AND 25-PERCENT REDUCTION OF HEPARIN DOSE IN CORONARY-ARTERY SURGERY - A CLINICAL-STUDY

被引:17
|
作者
BOROWIEC, J [1 ]
THELIN, S [1 ]
BAGGE, L [1 ]
VANDERLINDEN, J [1 ]
THORNO, E [1 ]
HANSSON, HE [1 ]
机构
[1] UNIV HOSP UPPSALA,DEPT ANESTHESIOL,S-75185 UPPSALA,SWEDEN
关键词
D O I
10.3109/03009739209179282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiopulmonary bypass with systemic heparinization causes trauma to blood cells and coagulation defects. Artificial surfaces could be coated by end-linkage binding of heparin (Carmeda Bioactive Surface, CBAS(TM)) . Use of such surfaces during cardiopulmonary bypass in animals resulted in less postoperative blood loss and better preservation of blood cells. In this study heparin-coated circuits were employed during coronary artery grafting in 7 patients (Group HC). Concomitantly, the heparin dose was reduced by 25% and an activated clotting time (ACT) of 300 sec was accepted. Additional 7 patients were operated with standard circuits (Group C), requiring ACT above 400 sec with normal doses of heparin. There were no thromboembolic complications in Group HC. The postoperative bleeding was generally low and without significant intergroup differences. Coagulation parameters displayed significantly lower ACT and anti-Factor Xa during bypass in Group HC. A tendency towards less blood cell trauma was observed with heparin-coated circuits. The protamine dose could be reduced by 50%, which significantly reduced the protamine/heparin quotient. This study indicates that routine cardiopulmonary bypass could be performed safely with heparin-coated circuits and reduced intravenous doses of heparin and protamine. It is suggested that the use of heparin-coated circuits may lead to less blood cell trauma.
引用
收藏
页码:55 / 66
页数:12
相关论文
共 50 条
  • [1] Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery
    Horimoto, H
    Kondo, K
    Asada, K
    Sasaki, S
    ARTIFICIAL ORGANS, 1996, 20 (08) : 936 - 940
  • [2] Clinical outcome after coronary surgery with heparin-coated extracorporeal circuits for cardiopulmonary bypass
    Baufreton, Christophe
    Le Besnerais, Paul
    Jansen, Piet
    Mazzucotelli, Jean Philippe
    Wildevuur, Charles R. H.
    Loisance, Daniel Y.
    PERFUSION-UK, 1996, 11 (06): : 437 - 443
  • [3] HEPARIN-COATED CIRCUITS REDUCE ACTIVATION OF GRANULOCYTES DURING CARDIOPULMONARY BYPASS - A CLINICAL-STUDY
    BOROWIEC, J
    THELIN, S
    BAGGE, L
    NILSSON, L
    VENGE, P
    HANSSON, HE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (03): : 642 - 647
  • [4] Clinical use of heparin-coated cardiopulmonary bypass in coronary artery bypass grafting
    Mirow, N
    Minami, K
    KLeikamp, G
    Tenderich, G
    Puhlmann, T
    Körfer, R
    THORACIC AND CARDIOVASCULAR SURGEON, 2001, 49 (03): : 131 - 136
  • [5] Coronary artery bypass surgery with heparin-coated perfusion circuits and low-dose heparinization
    Mullen, JC
    Bentley, MJ
    Gelfand, ET
    Koshal, A
    Modry, DL
    Guenther, CR
    Etches, WS
    Stang, LJ
    Lopushinsky, SR
    CANADIAN JOURNAL OF SURGERY, 2002, 45 (03) : 166 - 172
  • [6] Clinical evaluation of heparin-coated circuits for routine coronary artery bypass grafting surgery:: A prospective randomized study
    Collart, F
    Caus, T
    Pomane, C
    Pellissier, V
    Chi, Y
    Montiès, JR
    Mesana, T
    ARTIFICIAL ORGANS, 2000, 24 (08) : 611 - 613
  • [7] BIOCOMPATIBILITY OF HEPARIN-COATED CIRCUITS USED IN CARDIOPULMONARY BYPASS
    PEKNA, M
    BOROWIEC, J
    FAGERHOL, MK
    VENGE, P
    THELIN, S
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 28 (01): : 5 - 11
  • [8] Heparin-coated bypass circuits in cardiopulmonary bypass: Improved biocompatibility or not
    Levy, M
    Hartman, AR
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 53 : S81 - S87
  • [9] Heparin-coated cardiopulmonary bypass circuits: current status
    Hsu, LC
    PERFUSION-UK, 2001, 16 (05): : 417 - 428
  • [10] Biocompatibility of heparin-coated circuits in pediatric cardiopulmonary bypass
    Kagisaki, K
    Masai, T
    Kadoba, K
    Sawa, Y
    Nomura, F
    Fukushima, N
    Ichikawa, H
    Ohata, T
    Suzuki, K
    Taketani, S
    Matsuda, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 836 - 840