THE EFFECT OF DRILLING PARAMETERS ON BONE .2. THE INFLUENCE OF DRILLING SITE

被引:1
|
作者
OHASHI, H [1 ]
THERIN, M [1 ]
MEUNIER, A [1 ]
CHRISTEL, P [1 ]
机构
[1] UNIV PARIS 07,FAC MED LARIBOISIERE ST LOUIS,CNRS,UA 1432,RECH ORTHOPED LAB,F-75010 PARIS,FRANCE
关键词
D O I
10.1007/BF00121094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For orthopaedic biomaterial implantation testing, specimens are often implanted into cortical bone defects. The implantation site is assumed to be one of the factors that influence the bone response to biomaterials. The aim of this study was to investigate the bone-healing process in drilled cortical defects at different sites with respect to time. Sheep metatarsus was implemented, since it is a long straight bone with four flat faces. Thus, the different drilling sites were obtained by changing the longitudinal level (proximal, middle and distal) and bone aspect (anterior, lateral and posterior). Metatarsi were obtained at 1, 2, 3 and 4 months post-operatively and with non-decalcified sections the newly formed bone area was measured using a microscope connected to an image analyser. The rate of bone formation was higher in the anterior aspect (P < 0.05). The new bone did not form concentrically from the hole edge towards the centre, and the principal direction of bone growth was different between the anterior and the posterior aspects (P < 0.05). However, there was no difference with respect to the longitudinal axis. These results indicate that the implantation site must be considered when analysing the bone response to biomaterials implanted in cortical defects.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 50 条
  • [2] Influence of Orthopaedic Drilling Parameters on Surface Roughness and Cutting Force of Bone Drilling Process
    Izamshah, R.
    Noorazizi, M. S.
    Kasim, M. S.
    Haron, C. H. Che
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ELECTRONICS, MECHANICS, CULTURE AND MEDICINE, 2016, 45 : 752 - 758
  • [3] INFLUENCE OF BONE DRILLING PARAMETERS ON THE THERMAL STRESS DISTRIBUTION
    Fernandes, Maria G.
    Fonseca, Elza M.
    Jorge, Renato N.
    IRF2016: 5TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE, 2016, : 517 - 528
  • [4] Influence of drilling parameters on bone drilling force and temperature by FE simulation and parameters optimization based Taguchi method
    Tian, Heqiang
    Dang, Xiaoqing
    Meng, Debao
    Tian, Bin
    Li, Jianyong
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 75 : 115 - 126
  • [5] Drilling of bone: thermal osteonecrosis regions induced by drilling parameters
    Akhbar, Mohd Faizal Ali
    Yusoff, Ahmad Razlan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (06):
  • [6] Influence of different parameters on bone heating and drilling time in implantology
    Reingewirtz, Y
    SzmuklerMoncler, S
    Senger, B
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 189 - 197
  • [7] Study on the influence of parameters of medical drill on bone drilling temperature
    Xu, Xianchun
    Hu, Yahui
    Han, Jingwang
    Yue, Lin
    Jiang, Wangbiao
    2017 2ND INTERNATIONAL CONFERENCE ON MECHATRONICS AND ELECTRICAL SYSTEMS (ICMES 2017), 2018, 339
  • [8] Effect of Drilling Parameters on Machining Performance in Drilling Polytetrafluoroethylene
    Ni, Jing
    Zeng, Xiaotian
    Al-Furjan, M. S. H.
    Zhao, Huijun
    Guan, Liming
    Cui, Zhi
    Han, Lidong
    MATERIALS, 2022, 15 (19)
  • [10] The influence of crescent texture parameters on the axial force when drilling bone
    Hu, Yahui
    Chen, Xiannian
    Chen, Jin
    Zhang, Chunqiu
    Fu, Weihua
    MEDICAL ENGINEERING & PHYSICS, 2021, 87 : 87 - 94