EVALUATION OF ITERATIVE INTERPOLATION METHODS FOR METAL ARTEFACTS REDUCTION OF PELVIC COMPUTED TOMOGRAPHY IMAGES: A PHANTOM STUDY

被引:0
|
作者
Kaewlek, Titipong [1 ]
机构
[1] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok 65000, Thailand
关键词
Metal artefact reduction; Sinogram completion; Iterative interpolation; CT image;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Metal artefacts obscure the organs as shown on a computed tomography (CT) image. The effect of the artefact can be reduced by using sinogram completion techniques. The aim of this study is to evaluate interpolation methods - linear interpolation (LI), total variation in painting (TV), high order total variation inpainting (HTV) for reducing the effect of the artefact. In this study, the sinogram completion technique applied on the simulated pelvic CT image of a hip prosthesis. Algorithms consist of four steps: 1) segment the metal region on the image, 2) transform the image into a sinogram and find the boundary of the metal sinogram, 3) estimate the new value of the missing data using three different methods 4) reconstruct the modified sinogram and add back the metal region into the reconstructed image. The percentages of the difference of intensity value between the artefact image and the non-artefact image of three techniques were computed. The percentages of artefact reduction were evaluated to compare the effectiveness of algorithms. The HTV method can provide the lowest difference of intensity value amongst three interpolation algorithms. The artefact reduction of the HTV method reduced 89.43%. The HTV technique could be used for solving the metal artefact problem effectively on CT images.
引用
收藏
页码:704 / 714
页数:11
相关论文
共 50 条
  • [1] Evaluation of Two Sinogram Interpolation Methods for Metal Artefacts Reduction in Computed Tomography
    Osman, Noor Diyana
    Sobri, Nurul Fathin Mohamad
    Achuthan, Anusha
    Saidun, Halimatul Asma
    Aziz, Mohd Zahri Abdul
    Shuaib, Ibrahim Lutfi
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 137 - 139
  • [2] Reduction of metal artefacts in computed tomography
    Oehler, M
    Pfaffmann, L
    Buzug, TM
    CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 1310 - 1310
  • [3] Metal Artifact Reduction in Pelvic Computed Tomography With Hip Prostheses Comparison of Virtual Monoenergetic Extrapolations From Dual-Energy Computed Tomography and an Iterative Metal Artifact Reduction Algorithmin a Phantom Study
    Higashigaito, Kai
    Angst, Florian
    Runge, Val M.
    Alkadhi, Hatem
    Donati, Olivio F.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (12) : 828 - 834
  • [4] Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study
    Abdalqader, Omarah N.
    Hjouj, Mohammad
    Aljamal, Mohammad
    Hjouj, Fawaz
    Abuzaid, Mohamed
    Mousa, Mahmoud
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2024,
  • [5] Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study
    Onishi, Hiromitsu
    Kockelkoren, Remko
    Kim, Tonsok
    Hori, Masatoshi
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Uranishi, Ayumi
    Tanaka, Toshiya
    Taniguchi, Akira
    Enchi, Yukihiro
    Satoh, Kazuhiko
    Tomiyama, Noriyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 629 - 634
  • [6] Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom
    Hakvoort, E. T.
    Wellenberg, R. H. H.
    Streekstra, G. J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 9 - 18
  • [7] Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
    Huang, V.
    Kohli, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3244 - 3244
  • [8] Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging
    Ishikawa, Takuya
    Suzuki, Shigeru
    Harashima, Shingo
    Fukui, Rika
    Kaiume, Masafumi
    Katada, Yoshiaki
    MEDICINE, 2020, 99 (50) : E23692
  • [9] Frequency split metal artefact reduction in pelvic computed tomography
    M. M. Lell
    E. Meyer
    M. Schmid
    R. Raupach
    M. S. May
    M. Uder
    M. Kachelriess
    European Radiology, 2013, 23 : 2137 - 2145
  • [10] Frequency split metal artefact reduction in pelvic computed tomography
    Lell, M. M.
    Meyer, E.
    Schmid, M.
    Raupach, R.
    May, M. S.
    Uder, M.
    Kachelriess, M.
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2137 - 2145