Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety

被引:0
|
作者
Artner, Juraj [1 ]
Cakir, Balkan [1 ]
Weckbach, Sebastian [2 ]
Reichel, Heiko [1 ]
Lattig, Friederike [1 ]
机构
[1] Univ Ulm, RKU, Dept Orthopaed Surg, D-89081 Ulm, Germany
[2] Univ Ulm, Dept Trauma Hand Plast & Reconstruct Surg, D-89075 Ulm, Germany
来源
关键词
CT-Guided spinal injections; Periradicular injection; Computed tomography; Lumbar spine; Low dose protocol;
D O I
10.1186/1754-9493-6-19
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Image guided spinal injections are successfully used in the management of low back pain and sciatica. The main benefit of CT-guided injections is the safe, fast and precise needle placement, but the radiation exposure remains a serious concern. The purpose of the study was to test a new institutional low-dose protocol for CT-guided periradicular injections in lumbar spine to reduce radiation exposure while increasing accuracy and safety for the patients. Methods:We performed a retrospective analysis of a prospective database during a 4-month period (Oct-Dec 2011) at a German University hospital using a newly established low-dose-CT-protocol for periradicular injections in patients suffering from lumbar disc herniation and nerve root entrapment. Inclusion criteria were acute or chronic nerve root irritation due to lumbar disc hernia, age over 18, compliance and informed consent. Excluded were patients suffering from severe obesity (BMI > 30), coagulopathy, allergy to injected substances, infection and noncompliant patients. Outcome parameters consisted of the measured dose length product (mGycm2), the amount of scans, age, gender, BMI and the peri-interventional complications. The results were compared to 50 patients, treated in the standard-interventional CT-protocol for spinal injections, performed in June-Oct 2011, who met the above mentioned inclusion criteria. Results: A total amount of 100 patients were enrolled in the study. A significant radiation dose reduction (average 85.31%) was achieved using the institutional low-dose protocol compared to standard intervention mode in CT-guided periradicular injections in lumbar spine. Using the low-dose protocol did not increase the complications rate in the analyzed cohort. Conclusions: Low-dose-CT-protocols for lumbar perineural injections significantly reduce the exposure to radiation of non-obese patients without an increase of complications. This increases long-time patient safety of stochastic radiation effects.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety
    Juraj Artner
    Balkan Cakir
    Sebastian Weckbach
    Heiko Reichel
    Friederike Lattig
    Patient Safety in Surgery, 6 (1)
  • [2] Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
    Chang, A. L.
    Schoenfeld, A. H.
    Brook, A. L.
    Miller, T. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1882 - 1886
  • [3] CT-Guided Lumbar Nerve Root Injections: Are We Using the Correct Radiation Dose Settings?
    Schauberger, J. S.
    Kranz, P. G.
    Choudhury, K. R.
    Eastwood, J. D.
    Gray, L.
    Hoang, J. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (10) : 1855 - 1859
  • [4] Radiation Dose Reduction in CT-Guided Spine Biopsies Does Not Reduce Diagnostic Yield
    Shpilberg, K. A.
    Delman, B. N.
    Tanenbaum, L. N.
    Esses, S. J.
    Subramaniam, R.
    Doshi, A. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (12) : 2243 - 2247
  • [5] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Karolin J. Paprottka
    Karina Kupfer
    Vivian Schultz
    Meinrad Beer
    Claus Zimmer
    Thomas Baum
    Jan S. Kirschke
    Nico Sollmann
    Scientific Reports, 13
  • [6] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Paprottka, Karolin J.
    Kupfer, Karina
    Schultz, Vivian
    Beer, Meinrad
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] CT-Guided intervention with low radiation dose: Feasibility and experience
    Lucey, Brian C.
    Varghese, Jose C.
    Hochberg, Aaron
    Blake, Michael A.
    Soto, Jorge A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1187 - 1194
  • [8] Reducing Patient Radiation Dose during CT-Guided Procedures: Demonstration in Spinal Injections for Pain
    Shepherd, T. M.
    Hess, C. P.
    Chin, C. T.
    Gould, R.
    Dillon, W. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1776 - 1782
  • [9] Scout-guided needle placement—a technical approach for dose reduction in CT-guided periradicular infiltration
    Maximilian Nunninger
    Victor Paul Bela Braun
    Marco Ziegert
    Felix Benjamin Schwarz
    Bernd Hamm
    Michael Scheel
    Paul Jahnke
    Neuroradiology, 2020, 62 : 341 - 346
  • [10] Radiation dose during CT-guided percutaneous cryoablation of renal tumors: Effect of a dose reduction protocol
    Levesque, Vincent M.
    Shyn, Paul B.
    Tuncali, Kemal
    Tatli, Servet
    Nawfel, Richard D.
    Olubiyi, Olutayo
    Silverman, Stuart G.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2218 - 2221