Effect of yellow-tinted intraocular lens on standard automated perimetry and short wavelength automated perimetry in patients with glaucoma

被引:2
|
作者
Nilforushan, Naveed [1 ]
Parsamanesh, Mohammad [1 ]
Yu, Fei [2 ]
Nassiri, Nariman [2 ]
Miraftabi, Arezoo [1 ]
Coleman, Anne L. [1 ,2 ]
机构
[1] Iran Univ Med Sci, Rassoul Akram Hosp, Ophthalm Res Ctr, Dept Ophthalmol, Tehran, Iran
[2] Univ Calif Los Angeles, David Geffen Sch Med, Jules Stein Eye Inst, Glaucoma Div, Los Angeles, CA 90024 USA
关键词
Glaucoma; Standard Automated Perimetry; Short-Wavelength Automated Perimetry; Yellow-Tinted Intraocular Lens;
D O I
10.4103/0974-9233.134671
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. Materials and Methods: In this prospective comparative case series, phacoemulsification with implantation of yellow-tinted Acrysof Natural IOL was performed in 16 eyes of 16 patients with visually significant cataract (best-corrected visual acuity (VA) better than 20/120) and mild to moderate glaucoma. Pre- and postoperative values for VA and for perimetry indices including mean deviation (MD), pattern standard deviation (PSD), and foveal threshold (FT) from both SAP and SWAP testing were compared. Results: Postoperative VA improved significantly after cataract surgery and yellow-tinted IOL implantation (P < 0.001). After cataract extraction and IOL implantation, MD and FT on SWAP testing improved significantly (P = 0.001); however, there was no statistically significant change with SAP testing between the pre- and postoperative perimetry indices. There was no statistically significant change in PSD with either SAP or SWAP testing postoperatively. The differences between pre- and postoperative values for all perimetry indices under study were not significant when comparing SAP with SWAP tests, except for MD which had improved statistically significantly in SWAP testing (P = 0.03). Conclusions: In mild to moderate glaucoma patients with cataracts, the perimetry indices of SWAP testing improved after phacoemulsification and yellow-tinted IOL implantation. This suggests that the yellow-tinted IOLs have less effect on SWAP testing than visually significant cataracts.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 50 条
  • [1] Effect of Yellow-Tinted Intraocular Lenses on Short-Wavelength Automated Perimetry
    Mainster, Martin A.
    Turner, Patricia L.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (04) : 589 - 590
  • [2] Effect of Yellow-Tinted Intraocular Lenses on Short-Wavelength Automated Perimetry
    Jang, Sun Young
    Ohn, Young-Hoon
    Kim, Sun Woong
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (02) : 243 - 247
  • [3] Yellow-Tinted Intraocular Lenses on Short-Wavelength Automated Perimetry
    Ho, Jonathan Chun-Ho
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (02) : 380 - 380
  • [4] Effect of Yellow-Tinted Intraocular Lenses on Short-Wavelength Automated Perimetry REPLY
    Jang, Sun Young
    Kim, Sun Woong
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (04) : 590 - 591
  • [5] Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma
    Sample, PA
    Bosworth, CF
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) : 1129 - 1133
  • [6] A comparison of long term variability in standard automated perimetry and short-wavelength automated perimetry in stable glaucoma patients
    Blumenthal, EZ
    Sample, PA
    Zangwill, L
    Lee, AC
    Kono, Y
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S581 - S581
  • [7] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [8] Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
    Zhou, Han Peng
    Asaoka, Ryo
    Inoue, Tatsuya
    Asano, Shotaro
    Murata, Hiroshi
    Hara, Takumi
    Makino, So
    Kadonosono, Kazuaki
    Obata, Ryo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] Short wavelength automated perimetry and standard automated perimetry in central serous chorioretinopathy
    Han Peng Zhou
    Ryo Asaoka
    Tatsuya Inoue
    Shotaro Asano
    Hiroshi Murata
    Takumi Hara
    So Makino
    Kazuaki Kadonosono
    Ryo Obata
    Scientific Reports, 10
  • [10] Short-wavelength automated perimetry (SWAP) and motion automated perimetry (MAP) in glaucoma
    Sample, PA
    Bosworth, CF
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 977 - 977