USE OF ICP-MS FOR DETERMINING CASHMERE YIELD

被引:0
|
作者
STEINER, JW [1 ]
DENTON, PL [1 ]
机构
[1] QUEENSLAND DEPT PRIMARY IND, ANIM RES INST, YEERONGPILLY, QLD 4105, AUSTRALIA
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
After acid dissolution, the cashmere fiber samples were analyzed using ICP-MS. Of the 69 elements studied, only calcium and manganese met the requirements for estimating cashmere yield in fleece. Calcium appeared to be the most suitable indicator because it provided an excellent correlation between the predicted and experimentally determined values. Measurement of the variations in isotope ratios for cashmere and hair was difficult as the number of isotopes free from interferences is limited. The isotope ratios used in this study included Zn-64/Zn-66, Sn-118/Sn-120, Ba-135/Ba-137, Ba-135/Ba-136, Ba-135/Ba-138, Ba-137/Ba-138, Ba-136/Ba-138. Data obtained to date is encouraging, but more study is still needed.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 50 条
  • [1] Determining element species with ICP-MS
    Paul, Michael
    McSheehy, Shona
    NACHRICHTEN AUS DER CHEMIE, 2007, 55 (7-8) : 766 - 769
  • [2] ICP-MS changes increase use
    Studt, T
    R&D MAGAZINE, 1998, 40 (02): : 53 - 53
  • [3] Quantification of Proteins by Use of ICP-MS
    Zheng Lingna
    Wang Meng
    Wang Huajian
    Li Jianjun
    Feng Weiyue
    Chai Zhifang
    PROGRESS IN CHEMISTRY, 2010, 22 (11) : 2199 - 2206
  • [4] Optimisation of DRC ICP-MS for determining selenium in plants
    Sucharova, Julie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (09) : 1756 - 1762
  • [5] ICP-MS
    不详
    MICRO, 1995, 13 (02): : 44 - 44
  • [6] ICP-MS
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1986, 5 (08) : R8 - R8
  • [7] Guide for determining ICP/ICP-MS method detection limits and instrument performance
    Sivakumar, Vanaja
    Ernyei, Laszlo
    Obenauf, Ralph H.
    SPECTROSCOPY, 2006, : 13 - 13
  • [8] On the Use of ICP-MS for Measuring Plutonium in Urine
    N. Baglan
    C. Cossonnet
    P. Pitet
    D. Cavadore
    L. Exmelin
    P. Berard
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 397 - 401
  • [9] On the use of ICP-MS for measuring plutonium in urine
    Baglan, N
    Cossonnet, C
    Pitet, P
    Cavadore, D
    Exmelin, L
    Berard, P
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (02) : 397 - 401
  • [10] Single-cell analysis by use of ICP-MS
    Theiner, Sarah
    Loehr, Konrad
    Koellensperger, Gunda
    Mueller, Larissa
    Jakubowski, Norbert