ZONAL COULOMETRIC ANALYSIS OF THE CORROSION-RESISTANCE OF DENTAL ALLOYS

被引:28
|
作者
RECLARU, L
MEYER, JM
机构
[1] UNIV GENEVA,SCH DENT,DIV DENT MAT,CH-1211 GENEVA 4,SWITZERLAND
[2] METAUX PRECIEUX SA,METALOR,NEUCHATEL,SWITZERLAND
关键词
PRECIOUS DENTAL ALLOYS; NONPRECIOUS DENTAL ALLOYS; CORROSION; CORROSION POTENTIAL; POLARIZATION RESISTANCE; COULOMETRIC ANALYSIS; STATISTICAL DATA; RESPONSE SURFACE METHODOLOGY;
D O I
10.1016/0300-5712(95)91150-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The corrosion resistance of a series of 51 dental alloys and pure metals was evaluated by coulometric analysis. Methods: The method consisted of dividing the anodic polarization curves into three separate zones; zone I, from the open-circuit potential (after 24 h immersion) up to + 300 mV (SCE): zone II, from 300 mV to 700 mV (SCE); zone III, + 700 mV to 1000 mV (SCE). The surfaces below the curves are integrated for each zone and the results expressed in millicoulombs (mC). Results and conclusions: Although the intensity of degradation in the mouth may vary from patient to patient, we think that a potential danger may occur in zones I and II in particular. Coulometric analysis reveals that: (i) the alloys for the porcelain-fused-to metal (PFM) technique have a better corrosion resistance (2.58 mC on average for the sum of the three zones, against 283.7 mC for conventional alloys); (ii) the elements Cu, Ag and Ni reduce the corrosion resistance of gold-based alloys; (iii) within the same class, single-phase alloys resist better than two-phase alloys.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 50 条