DETERMINATION OF TRACE IMPURITY RARE-EARTH ELEMENTS IN HIGH-PURITY RARE-EARTH ELEMENT SAMPLES USING HIGH-RESOLUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:30
|
作者
TAKAKU, Y [1 ]
MASUDA, K [1 ]
TAKAHASHI, T [1 ]
SHIMAMURA, T [1 ]
机构
[1] KITASATO UNIV,SCH HYG SCI,SAGAMIHARA,KANAGAWA 228,JAPAN
关键词
HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; RARE EARTH ELEMENT; DOUBLY CHARGED SPECIES;
D O I
10.1039/ja9930800687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trace impurity rare earth elements in high-purity Y2O3 and Gd2O3 Were determined using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Interference problems from GdO, GdH and GdOH on Tb, Yb, Tm and Lu were overcome by using doubly charged ions for detection. The mass resolution was set to 400, which is much higher than the normal resolution (80-90) of a conventional quadrupole mass filter and much lower than the standard setting for ICP-MS in the high-resolution mode. As a result, the transmission decrease that occurs with a quadrupole mass filter if increased resolution is used was not a problem. The only controlling factor for the sensitivity was the production rate of doubly charged species. Hence optimization was applied to maximize the proportion of doubly charged species. The detection limits obtained were 0.05-3 ng 1(-1) in solution. If singly charged ions were used, the detection limits were 5-30 pg 1(-1). Determinations of trace rare earth elements in three Y2O3 and three Gd2O3 test samples were performed. The concentrations of the trace rare earth elements were found to be variable between the samples.