APPLICATION OF BESSEL BEAM FOR DOPPLER VELOCITY ESTIMATION

被引:40
|
作者
LU, JY
XU, XL
ZOU, HH
GREENLEAF, JF
机构
[1] Biodynamics Research Unit Department of Physiology and Biophysics, Mayo Clinic and Foundation, Rochester
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.393108
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Limited-diffraction beams have a large depth of field and could be applied to medical imaging, tissue characterization, and nondestructive evaluation of materials. This paper reports the application of limited diffraction beams, specifically, the Bessel beam, to Doppler velocity estimation, The Bessel beam has the advantage that velocity estimation is less subject to the depth of moving objects and the Doppler spectrum has distinct shoulders that increase the accuracy of velocity (both magnitude and Doppler angle) estimation in noisy environments, The shoulders of the Doppler spectrum might also help in solving the inverse problem, e.g., estimation of the velocity distribution in vessels.
引用
收藏
页码:649 / 662
页数:14
相关论文
共 50 条
  • [1] Beam steering in pulsed 'Doppler' ultrasound velocity estimation
    Steinman, AH
    Lui, EYL
    Johnston, KW
    Cobbold, RSC
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1745 - 1748
  • [2] A Bessel beam laser Doppler velocimeter
    Voigt, Andreas
    Heitkam, Sascha
    Buettner, Lars
    Czarske, Juergen
    OPTICS COMMUNICATIONS, 2009, 282 (09) : 1874 - 1878
  • [3] Measuring velocity with Bessel beam fringes
    Sakah, Mahmud
    Chebbi, Brahim
    Golub, Ilya
    OPTICAL ENGINEERING, 2015, 54 (08)
  • [4] Slowing of Bessel light beam group velocity
    Alfano, Robert R.
    Nolan, Daniel A.
    OPTICS COMMUNICATIONS, 2016, 361 : 25 - 27
  • [5] Estimation of Doppler Velocity Degradation Due to Difference in Beam-Pointing Directions
    Nakamura, Kenji
    Furukawa, Kinji
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2023, 20
  • [6] Comments on "Slowing of Bessel light beam group velocity
    Saari, Peeter
    OPTICS COMMUNICATIONS, 2017, 392 : 300 - 301
  • [7] Doppler angle and flow velocity estimation using conventional single-probing-beam optical Doppler tomography
    Piao, DQ
    Zhu, Q
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 : 232 - 243
  • [8] VELOCITY ESTIMATION BY BEAM STACK
    BIONDI, B
    GEOPHYSICS, 1992, 57 (08) : 1034 - 1047
  • [9] Response to comments on "Slowing of Bessel light beam group velocity"
    Alfano, Robert R.
    Nolan, Daniel A.
    OPTICS COMMUNICATIONS, 2017, 392 : 302 - 302
  • [10] Measurement of the superluminal group velocity of an ultrashort Bessel beam pulse
    Alexeev, I
    Kim, KY
    Milchberg, HM
    PHYSICAL REVIEW LETTERS, 2002, 88 (07) : 4 - 739014