THE USE OF THE ANTIGLOBULIN GEL-TEST FOR ANTIBODY DETECTION

被引:33
|
作者
PHILLIPS, PK
WHITTON, CM
LAVIN, F
机构
[1] National Institute for Biological Standards and Control, Potters Bar, EN6 3QG, Blanche Lane, South Mimmes
关键词
ANTIGLOBULIN; GET-TEST; SENSITIVITY;
D O I
10.1111/j.1365-3148.1992.tb00143.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Four antibodies used routinely in-house for the assessment of antiglobulin reagents (anti-Fy(b), anti-Jk(a), anti-S) were tested in parallel using tube and antiglobulin 'gel-test' low ionic strength antiglobulin techniques. In the latter the red cells are centrifuged following incubation through a dextran matrix incorporating an anti-human globulin reagent. The results show that the antiglobulin 'gel-test' was less sensitive than the tube technique in the detection of these difficult antibodies.
引用
收藏
页码:111 / 113
页数:3
相关论文
共 50 条
  • [1] Factors influencing antibody detection with the DiaMed gel antiglobulin test
    Cornish, C
    Flower, R
    TRANSFUSION MEDICINE, 2003, 13 (04) : 243 - 244
  • [2] EVALUATION OF A GEL-TEST SYSTEM FOR THE DETECTION OF TRANSPLACENTAL HEMORRHAGE
    ZAGONOVARETTI, MC
    JENS, E
    DORLHIACLLACER, PE
    CHAMONE, DAF
    TRANSFUSION, 1994, 34 (10) : S28 - S28
  • [3] Evaluation of gel-test technology in drug-induced positive direct antiglobulin tests.
    Sopeleti, CR
    Novaretti, MC
    Dorlhiac-Llacer, PE
    Chamone, DA
    TRANSFUSION, 2000, 40 (10) : 114S - 114S
  • [4] Comparison of the polyethylene glycol antiglobulin test and the use of enzymes in antibody detection and identification
    Reisner, R
    Butler, G
    Bundy, K
    Moore, SB
    TRANSFUSION, 1996, 36 (06) : 487 - 489
  • [5] GEL-TEST - INTERPRETATION AND VALUE OF A NEW TECHNIQUE FOR THE DETECTION OF IRREGULAR ANTIBODIES
    POTTIER, C
    QUILLET, P
    BAUFINEDUCROCQ, H
    ANNALES DE BIOLOGIE CLINIQUE, 1992, 50 (10-11) : 679 - 685
  • [6] The use of papain treated panel cells with indirect antiglobulin test gel cards as an aid to antibody identification
    Stamps, R
    Booker, DJ
    Powell, G
    Eggington, J
    Burgess, G
    TRANSFUSION, 2005, 45 (03) : 120A - 120A
  • [7] EVALUATION OF A GEL-TEST SYSTEM FOR ABO/RH-TYPING AND DIRECT ANTIGLOBULIN TESTING IN FETUSES UNDERGOING 2 INTRAUTERINE TRANSFUSIONS
    ZAGONOVARETTI, MC
    KONDO, MM
    JENS, E
    ZUGAIB, M
    FERREIRA, F
    DORLHIACLLACER, PE
    CHAMONE, DAF
    TRANSFUSION, 1993, 33 (09) : S19 - S19
  • [8] AN ANTIBODY SCREENING-TEST BASED ON THE ANTIGLOBULIN GEL TECHNIQUE, POOLED TEST CELLS, AND PLASMA
    LILLEVANG, ST
    GEORGSEN, J
    KRISTENSEN, T
    VOX SANGUINIS, 1994, 66 (03) : 210 - 215
  • [9] Comparison of low ionic diluents for use with the DiaMed antiglobulin gel test
    Grey, D
    TRANSFUSION MEDICINE, 2002, 12 (05) : 330 - 330
  • [10] Comparison of low ionic diluents for use with the Diamed antiglobulin gel test
    Grey, D
    Connolly, M
    Erber, WN
    TRANSFUSION MEDICINE, 2002, 12 (01) : 63 - 69