QUANTIFICATION OF CHEMILUMINESCENT DNA PROBES USING LIQUID SCINTILLATION-COUNTING

被引:6
|
作者
SELPH, KE
KARL, DM
LANDRY, MR
机构
[1] School of Ocean and Earth Science and Technology, Department of Oceanography, University of Hawaii at Manoa, Honolulu, HI 96822
关键词
D O I
10.1006/abio.1993.1213
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method for quantifying chemiluminescent DNA probes is described. The method uses liquid scintillation counting to measure light emission from the alkaline phosphatase-catalyzed breakdown of the substrate PPD (3-(4-methoxyspiro[1,2-dioxetane-3,2'-tricyclo[3.3.1.13,7]decan]-4- yl)phenyl phosphate) on dot blot preparations. Serial dilutions of either pUC18 DNA or λ DNA were hybridized with digoxigenin-labeled probes and detected using the method described. Light flux (luminescence) was linearly related to DNA concentration, typically with a coefficient of determination (r2) of 0.9 or better. Due to the stability of alkaline phosphatase and the long-lived luminescence of PPD in the Lumi-phos formulation, repetitive analyses of a given sample can be made for up to 20 h. The method can reliably detect 17 amol of DNA (30 pg pUC18 DNA) with a coefficient of variation on replicate samples of 14%. Optimization experiments showed that 7% sodium dodecyl sulfate in the prehybridization and hybridization buffers resulted in the lowest background; the best combination of signal-to-noise ratio and reproducibility was obtained using Bio-Rad Zeta-Probe GT nylon membranes. Direct immersion of samples into a solution of substrate was found to give the most precise results and ensured that substrate limitation at high concentrations of alkaline phosphatase (i.e., higher DNA amounts) did not occur. © 1994 Academic Press, Inc. All rights reserved.
引用
收藏
页码:394 / 401
页数:8
相关论文
共 50 条
  • [1] CHEMILUMINESCENT EFFECT ENCOUNTERED IN LIQUID SCINTILLATION-COUNTING OF P-32 PHOSPHATE
    BELL, TK
    LAPPIN, TRJ
    ANNALS OF CLINICAL BIOCHEMISTRY, 1978, 15 (JAN) : 37 - 39
  • [2] LIQUID SCINTILLATION-COUNTING OF CHLOROPHYLL
    FRIC, F
    HASPELHORVATOVIC, E
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1975, 26 (09): : 509 - 514
  • [3] LIQUID SCINTILLATION-COUNTING OF PORPHYRINS
    ARONOFF, S
    SHIPLEY, J
    DEAKIN, BJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1985, 36 (03): : 223 - 225
  • [4] USING SIS TO COMPUTE DPM BY LIQUID SCINTILLATION-COUNTING
    RING, JG
    EVERETT, LJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 38 - 39
  • [5] LIQUID SCINTILLATION-COUNTING IN THE LONDON UNDERGROUND
    BOWMAN, S
    RADIOCARBON, 1989, 31 (03) : 393 - 398
  • [6] TOXICITY CONSIDERATIONS IN LIQUID SCINTILLATION-COUNTING
    MOGHISSI, AA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 23 - 24
  • [7] RADIOACTIVITY STANDARDIZATION FOR AND BY LIQUID SCINTILLATION-COUNTING
    MANN, WB
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (01): : 10 - 10
  • [8] THE PROBLEM OF INSTABILITY IN LIQUID SCINTILLATION-COUNTING
    RADIMIR, R
    RICHARD, T
    APPLIED RADIATION AND ISOTOPES, 1990, 41 (09) : 867 - 871
  • [9] BIODEGRADABLE LIQUID SCINTILLATION-COUNTING COCKTAILS
    KLEIN, RC
    GERSHEY, EL
    HEALTH PHYSICS, 1990, 59 (04): : 461 - 470
  • [10] LIQUID SCINTILLATION-COUNTING OF POSITRON EMITTERS
    MCQUARRIE, SA
    NOUJAIM, AA
    EDISS, C
    WIEBE, LI
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 27 - 28