Analysis, Design, and Construction of a Base-Isolated Multiple Building Structure

被引:18
|
作者
Sorace, Stefano [1 ]
Terenzi, Gloria [2 ]
机构
[1] Univ Udine, Dept Civil Engn & Architecture, Via Sci 206, I-33100 Udine, Italy
[2] Univ Florence, Dept Civil & Environm Engn, I-50139 Florence, Italy
关键词
D O I
10.1155/2014/585429
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75min the longitudinal direction and about 30malong the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated "artificial ground" ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance, and a finer architectural look, as compared to a conventional fixed-base antiseismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the nonlinear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants and highlights of the construction works.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Design and analysis of LRB base-isolated building structure for multilevel performance targets
    Hu, Guang-Jie
    Ye, Kun
    Tang, Zhen-Yun
    STRUCTURES, 2023, 57
  • [2] NONLINEAR DYNAMIC ANALYSIS OF MULTIPLE BUILDING BASE-ISOLATED STRUCTURES
    TSOPELAS, PC
    NAGARAJAIAH, S
    CONSTANTINOU, MC
    REINHORN, AM
    COMPUTERS & STRUCTURES, 1994, 50 (01) : 47 - 57
  • [3] Design considerations for a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 761 - 776
  • [4] Design case research for collision analysis of base-isolated building with retaining wall
    Onishi, Yoshihiro
    Komaki, Jumpei
    Takiyama, Noriko
    Hayashi, Yasuhiro
    AIJ Journal of Technology and Design, 2013, 19 (41) : 43 - 46
  • [5] Floor design response spectrum of base-isolated structure
    Dang Y.
    Li G.
    Xie P.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (07): : 321 - 332
  • [6] Analysis for The 3-dimensinonal Time history Response of a Base-isolated Building Structure
    Kang, Jinxia
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1961 - 1964
  • [7] Comparison of Seismic Response Characteristics Between Non Base-isolated and Base-isolated Building
    Enomoto, Takahisa
    Ninomiya, Masayuki
    Navarro, Manuel
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 2797 - 2804
  • [8] Optimal Design of Nontraditional Tuned Mass Damper for Base-Isolated Building
    Li, Dawei
    Ikago, Kohju
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (10) : 2841 - 2862
  • [9] Design of Base-Isolated Building as Per Indian Code Provisions and Practices
    Matsagar, Vasant
    Jain, Ratish
    SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 349 - 360
  • [10] Seismic performance of a base-isolated demonstration building
    Taniwangsa, W