CALCULATION OF THE NEUTRON AMBIENT DOSE EQUIVALENT ON THE BASIS OF THE ICRP REVISED QUALITY FACTORS

被引:0
|
作者
LEUTHOLD, G
MARES, V
SCHRAUBE, H
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
On the basis of new radiobiological findings, the ICRP has recently revised the LET dependence of the quality factor Q(LET) for charged particles. In consequence, many in-phantom defined radiation protection quantities have to be re-evaluated. Among these, the most important operational quantity in radiation protection is the ambient dose equivalent h*(10). This study deals with the calculation of h*(10), as defined at a depth of 10 mm in the ICRU sphere for a broad parallel neutron beam. Additionally, the ratio of ambient dose equivalent to ambient dose, the effective quality factor q*eff, as function of neutron energy, is derived.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 50 条