OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM

被引:181
|
作者
GEHRICH, JL [1 ]
LUBBERS, DW [1 ]
OPITZ, N [1 ]
HANSMANN, DR [1 ]
MILLER, WW [1 ]
TUSA, JK [1 ]
YAFUSO, M [1 ]
机构
[1] MAX PLANCK INST SYST PHYSIOL, D-4600 DORTMUND, FED REP GER
关键词
D O I
10.1109/TBME.1986.325886
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:117 / 132
页数:16
相关论文
共 50 条
  • [1] THE EVALUATION OF A NEW INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM IN THE PIG
    CLUTTONBROCK, TH
    FINK, S
    MARKLE, D
    LUTHRA, AJ
    HENDRY, SP
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (06): : 387 - 391
  • [2] OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD GAS MONITORING SYSTEM.
    Gehrich, John L.
    Luebbers, Dietrich W.
    Opitz, Norbert
    Hansmann, Douglas R.
    Miller, William W.
    Tusa, James K.
    Yafuso, Maseo
    1600, (BME-33):
  • [3] THE PB3300 INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    LUMSDEN, T
    MARSHALL, WR
    DIVERS, GA
    RICCITELLI, SD
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (01): : 59 - 66
  • [4] MULTISITE EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    LARSON, CP
    VENDER, J
    SEIVER, A
    ANESTHESIOLOGY, 1994, 81 (03) : 543 - 552
  • [5] CLINICAL-ASSESSMENT OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    UCHIDA, T
    MAKITA, K
    TSUNODA, Y
    TOYOOKA, H
    AMAHA, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (01): : 64 - 70
  • [6] EVALUATION OF A BEDSIDE ARTERIAL BLOOD-GAS MONITORING-SYSTEM IN CRITICALLY ILL PATIENTS
    CANE, RD
    CHRISTIE, JM
    PERUZZI, WT
    SHAPIRO, BA
    ANESTHESIA AND ANALGESIA, 1993, 76 (02): : S34 - S34
  • [7] VALIDITY OF THE CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM DURING LIVER-TRANSPLANTATION
    NAKATSUKA, M
    POSNER, M
    FISHER, R
    RIGONI, J
    BOWEN, T
    BEESTON, J
    ANESTHESIOLOGY, 1994, 81 (3A) : A614 - A614
  • [8] Blood-gas monitoring
    Terzi, R. G. G.
    Anaesthesia, Pain, Intensive Care and Emergency Medicine, 2005, : 471 - 491
  • [9] PROGRESS IN THE DEVELOPMENT OF A FLUORESCENT INTRAVASCULAR BLOOD-GAS SYSTEM IN MAN
    MAHUTTE, CK
    SASSOON, CSH
    MURO, JR
    HANSMANN, DR
    MAXWELL, TP
    MILLER, WW
    YAFUSO, M
    JOURNAL OF CLINICAL MONITORING, 1990, 6 (02): : 147 - 157
  • [10] CLINICAL-ASSESSMENT OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM (VOL 41, PG 64, 1994)
    UCHIDA, T
    MAKITA, K
    TSUNODA, Y
    TOYOOKA, H
    AMAHA, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (07): : 658 - 658