Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial

被引:6
|
作者
Wai, Abraham K. C. [1 ]
Graham, Colin A. [1 ]
机构
[1] Chinese Univ Hong Kong, Accid & Emergency Med Acad Unit, Room 02C47,2-F,Main Clin Block, Shatin, Hong Kong, Peoples R China
来源
关键词
Intubation; Laryngoscopy; Ramped position; Supine position; Tracheal;
D O I
10.15441/ceem.15.048
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective To investigate the time to tracheal intubation using Glidescope videolaryngoscopy (GVL) compared to that of standard laryngoscopy, by using a Macintosh blade (SLM) in a human patient simulator in supine and elevated (ramped) positions. Methods In this randomized crossover design, novice intubators (first-year medical students), using both laryngoscopic techniques, attempted tracheal intubation on a human patient simulator with a "normal airway" anatomy (Cormack-Lehane grade I). The simulator was placed in both supine and ramped positions using a commercial mattress system. The mean time to intubation and complications were compared between GVL and SLM in both positions. The percentage of glottic opening (POGO, GVL only) was estimated during intubation in the ramped and supine positions. The primary outcome was time to intubation, and the secondary outcomes included complication rates such as esophageal intubation and dental trauma. Results There was no difference in the mean time to intubation in either position (P=0.33). The SLM intubation was significantly faster than GVL (mean difference, 1.5 minutes; P<0.001). The mean POGO score for GVL improved by 8% in the ramped position compared to that in supine position (P=0.018). The esophageal intubation rate for SLM was 15% to 17% compared to 1.3% for GVL; dental trauma occurred in 53% to 56% of GVL, compared to 2% to 6% for SLM (P < 0.001, respectively). Conclusion Novices had shorter intubation times using standard laryngoscopy with a SLM compared to GVL in both supine and ramped positions. GVL resulted in fewer esophageal intubations, but more dental trauma than standard laryngoscopy.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 39 条
  • [1] Effect of cooled tracheal tubes on time to intubate and first pass intubation success in novice intubators: A randomized crossover manikin study
    Tatliparmak, Ali Cankut
    Yilmaz, Sarper
    Aydin, Omerul Faruk
    Yurttas, Tahir Talat
    Ak, Rohat
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2023, 50
  • [2] Laryngoscopy and Tracheal Intubation in the Head-Elevated Position in Obese Patients: A Randomized, Controlled, Equivalence Trial
    Rao, Srikantha L.
    Kunselman, Allen R.
    Schuler, H. Gregg
    DesHarnais, Susan
    ANESTHESIA AND ANALGESIA, 2008, 107 (06): : 1912 - 1918
  • [3] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Łukasz Szarpak
    Łukasz Czyżewski
    Andrzej Kurowski
    Zenon Truszewski
    European Journal of Pediatrics, 2015, 174 : 1325 - 1332
  • [4] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Kurowski, Andrzej
    Truszewski, Zenon
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (10) : 1325 - 1332
  • [5] Comparing the posture and comfort of anaesthesiologists during laryngoscopy and tracheal intubation in the head-elevated laryngoscopy position in supine position and with a 25° backup: A randomised clinical crossover trial
    Mookambika, R.
    Kumar, R. V. Hemanth
    Areti, Archana
    Jaya, V
    INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (06) : 547 - 552
  • [6] Blind tracheal intubation through iLTS-D versus direct laryngoscopy by novice intubators during manual in-line neck stabilization: A randomized controlled trial
    Shavit, Itai
    Gaitini, Luis
    Matter, Ibrahim
    Swaid, Forat
    Safadi, Anan
    Badarna, Manar
    Almog, Ofer
    Baruch, Erez Nissim
    Lipsky, Ari Moshe
    Somri, Mostafa
    JOURNAL OF CLINICAL ANESTHESIA, 2021, 72
  • [7] Comparison of Macintosh Laryngoscopy in Bed-up-Head-Elevated Position With GlideScope Laryngoscopy: A Randomized, Controlled, Noninferiority Trial
    Tsan, Samuel E. H.
    Lim, Siu M.
    Abidin, Mohd F. Z.
    Ganesh, Shahmini
    Wang, Chew Y.
    ANESTHESIA AND ANALGESIA, 2020, 131 (01): : 210 - 219
  • [8] Tracheal intubation during chest compressions using Pentax-AWSA®, GlideScopeA®, and Macintosh laryngoscope: a randomized crossover trial using a mannequin
    Shin, Dong Hyuk
    Choi, Pil Cho
    Han, Sang Kuk
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (08): : 733 - 739
  • [9] Comparison of ETView SL, Airtraq, and Macintosh laryngoscopes for face-to-face tracheal intubation: a randomized crossover manikin trial
    Madziala, Agnieszka
    Majer, Jolanta
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1893 - 1894
  • [10] Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
    Eun Hee Chun
    Mi Hwa Chung
    Jung Eun Kim
    Kyung Mi Kim
    Hye Sun Lee
    Jung Mo Son
    Jiho Park
    Joo Hyun Jun
    BMC Anesthesiology, 22