CLINICAL-EXPERIENCES WITH THE GORE-TEX 5-PTFE CRUCIATE-LIGAMENT PROSTHESIS - GREATER-THAN-4-YEAR FOLLOW-UP

被引:0
|
作者
VOGEL, UB
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
In the last five years over 300 replacements of anterior and posterior cruciate ligaments have been done with the artificial prosthesis Gore-Tex (expanded PTFE, Polytetrafluorethylen) in our hospital. In several cases the PTFE-prosthesis proved to be favourable compared to the autologue grafts. The indication to an implantation of these prosthesis is to be set strictly. The benefits of this artificial prosthesis are: excellent biocompatibility, easy operative handling (implantation by arthroscopy), immediate post-operative fixation and full load capacity, quickly obtain original mobility, reduced rehabilitation time. The new compact diameter design (50 cases) presents improvements as against the previous Gore-Tex, concerning the implantation and possibility of rupture.
引用
收藏
页码:943 / 947
页数:5
相关论文
共 14 条
  • [1] THE GORE-TEX ANTERIOR CRUCIATE LIGAMENT PROSTHESIS - A LONG-TERM FOLLOW-UP
    PAULOS, LE
    ROSENBERG, TD
    GREWE, SR
    TEARSE, DS
    BECK, CL
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (03): : 246 - 252
  • [2] SYSTEMIC-PULMONARY ARTERY SHUNT USING PTFE PROSTHESIS (GORE-TEX) - EARLY RESULTS AND LONG-TERM FOLLOW-UP ON 105 CONSECUTIVE CASES
    DIBENEDETTO, G
    TIRABOSCHI, R
    VANINI, V
    ANNECCHINO, P
    AIAZZI, L
    CAPRIOLI, C
    PARENZAN, L
    THORACIC AND CARDIOVASCULAR SURGEON, 1981, 29 (03): : 143 - 147
  • [3] CRUCIATE LIGAMENT PROSTHESIS VS AUGMENTATION - A RANDOMIZED, PROSPECTIVE 5-YEAR FOLLOW-UP OF 41 CASES
    DAHLSTEDT, L
    DALEN, N
    JONSSON, U
    ADOLPHSON, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (04): : 431 - 433
  • [4] Anterior cruciate ligament reconstruction using biodegradable transfemoral fixation at 5-year follow-up: clinical and magnetic resonance imaging evaluation
    Nebelung, Sven
    Deitmer, Gregor
    Gebing, Rolf
    Reichwein, Frank
    Nebelung, Wolfgang
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (11) : 2279 - 2286
  • [5] STEM LOOSENING MORE COMMON WITH ITH THAN LUBINUS PROSTHESIS - A 5-YEAR CLINICAL AND RADIOGRAPHIC FOLLOW-UP OF 142 PATIENTS
    JACOBSSON, SA
    IVARSSON, I
    DJERF, K
    WAHLSTROM, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (05): : 425 - 431
  • [6] Anterior cruciate ligament reconstruction using biodegradable transfemoral fixation at 5-year follow-up: clinical and magnetic resonance imaging evaluation
    Sven Nebelung
    Gregor Deitmer
    Rolf Gebing
    Frank Reichwein
    Wolfgang Nebelung
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2279 - 2286
  • [7] Prospective Clinical and Radiographic Outcomes After Concomitant Anterior Cruciate Ligament Reconstruction and Meniscal Allograft Transplantation at a Mean 5-Year Follow-up
    Saltzman, Bryan M.
    Meyer, Maximilian A.
    Weber, Alexander E.
    Poland, Sarah G.
    Yanke, Adam B.
    Cole, Brian J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2017, 45 (03): : 550 - 562
  • [8] Holmium laser enucleation of the prostate versus open prostatectomy for prostates greater than 100 grams: 5-year follow-up results of a randomised clinical trial
    Kuntz, Rainer M.
    Lehrich, Karin
    Ahyai, Sascha A.
    EUROPEAN UROLOGY, 2008, 53 (01) : 160 - 168
  • [9] Effects of higher femoral tunnels on clinical outcomes, MRI, and second-look findings in double-bundle anterior cruciate ligament reconstruction with a minimal 5-year follow-up
    Lin, Lin
    Wang, Haijun
    Wang, Jian
    Wang, Yongjian
    Chen, Yourong
    Yu, Jiakuo
    CHINESE MEDICAL JOURNAL, 2024, 137 (04) : 465 - 472
  • [10] Effects of higher femoral tunnels on clinical outcomes, MRI, and second-look findings in double-bundle anterior cruciate ligament reconstruction with a minimal 5-year follow-up
    Lin Lin
    Wang Haijun
    Wang Jian
    Wang Yongjian
    Chen Yourong
    Yu Jiakuo
    中华医学杂志英文版, 2024, 137 (04)