A RADIOIMMUNOASSAY FOR THE QUANTIFICATION OF HUMAN UBIQUITIN IN BIOLOGICAL-FLUIDS - APPLICATION TO PARASITIC AND ALLERGIC DISEASES

被引:29
|
作者
ASSEMAN, C
PANCRE, V
DELANOYE, A
CAPRON, A
AURIAULT, C
机构
[1] Centre d'Immunologie et de Biologie Parasitaire, Institut Pasteur, 59019 Lille Cedex, 1 rue du Pr.A. Calmette
关键词
UBIQUITIN; RADIOIMMUNOASSAY; SCHISTOSOMIASIS; HYMENOPTERA VENOM HYPERSENSITIVITY; DESENSITIZATION;
D O I
10.1016/0022-1759(94)90286-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Purified ubiquitin has been shown to share similar biological and physicochemical properties with a previously characterized lymphokine, platelet activity suppressive lymphokine (PASL). This lymphokine, which inhibits the cytotoxic function of activated platelets, is produced during schistosomiasis and Hymenoptera venom hypersensitivity (HVH). We have developed a radioimmunoassay specific for ubiquitin, in order to determine the ubiquitin levels in human sera and plasma from patients with these pathologies. The working range of the assay was between 60 and 500 ng/ml, and the sensitivity was 8-10 ng/ml. The reproducibility, specificity and accuracy were determined under standard condition (PBS-0.3% BSA) and using different biological fluids (human serum, plasma and T lymphocyte supernatant). Using this assay, we found that the ubiquitin concentrations were higher in both schistosomiasis and HVH (up to 150-300 ng/ml) compared with sera and plasma from healthy donors where the ubiquitin levels did not exceed 50 ng/ml.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 50 条
  • [1] RADIOIMMUNOASSAY OF GLANDULAR KALLIKREINS IN HUMAN BIOLOGICAL-FLUIDS
    BAGSHAW, A
    BHOOLA, KD
    WHICHER, JT
    BRITISH JOURNAL OF PHARMACOLOGY, 1981, 74 (04) : P806 - P807
  • [2] RADIOIMMUNOASSAY OF STEROIDS IN BIOLOGICAL-FLUIDS
    ABRAHAM, GE
    CLINICAL BIOCHEMISTRY, 1974, 7 (03) : 193 - 201
  • [3] RADIOIMMUNOASSAY OF METHOTREXATE IN BIOLOGICAL-FLUIDS
    BOHUON, C
    DUPREY, F
    BOUDENE, C
    CLINICA CHIMICA ACTA, 1974, 57 (03) : 263 - 267
  • [4] RADIOIMMUNOASSAY OF STEROIDS IN BIOLOGICAL-FLUIDS
    ABRAHAM, GE
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1975, 6 (3-4): : 261 - 270
  • [5] RADIOIMMUNOASSAY OF INDOMETHACIN IN BIOLOGICAL-FLUIDS
    HARE, LE
    DITZLER, CA
    DUGGAN, DE
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (04) : 486 - 489
  • [6] RADIOIMMUNOASSAY FOR ERGOT ALKALOIDS IN BIOLOGICAL-FLUIDS
    KOSKINEN, EH
    KLEIMOLA, T
    ACTA PHYSIOLOGICA SCANDINAVICA, 1976, : 122 - 122
  • [7] A RADIOIMMUNOASSAY FOR PHYSOSTIGMINE IN BIOLOGICAL-FLUIDS AND TISSUES
    MILLER, RL
    VERMA, PS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (08) : 955 - 963
  • [8] THE DEVELOPMENT OF A RADIOIMMUNOASSAY FOR RANITIDINE IN BIOLOGICAL-FLUIDS
    JENNER, WN
    MARTIN, LE
    WILLOUGHBY, BA
    FELLOWS, I
    LIFE SCIENCES, 1981, 28 (12) : 1323 - 1329
  • [9] DEVELOPMENT OF A RADIOIMMUNOASSAY FOR PROPRANOLOL IN BIOLOGICAL-FLUIDS
    MARKS, V
    MOULD, GP
    STOUT, G
    WILLIAMS, S
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1978, 5 (04) : P371 - P371
  • [10] THE DEVELOPMENT OF A RADIOIMMUNOASSAY FOR RANITIDINE IN BIOLOGICAL-FLUIDS
    FELLOWS, I
    JENNER, WN
    MARTIN, LE
    WILLOUGHBY, BA
    BRITISH JOURNAL OF PHARMACOLOGY, 1981, 73 (01) : P274 - P275