3-DIMENSIONAL SPATIAL REGISTRATION AND INTERACTIVE DISPLAY OF POSITION AND ORIENTATION OF REAL-TIME ULTRASOUND IMAGES

被引:113
|
作者
KING, DL
KING, DL
SHAO, MYC
机构
关键词
D O I
10.7863/jum.1990.9.9.525
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound images may be difficult to interpret because of the lack of an image orientation display. To resolve this problem, a three-dimensonal (3-D) ultrasound scanner has been constructed that provides spatial registration and display of position and orientation of real-time images while allowing unconstrained movement of the scanning transducer. It consists of a conventional sector scanner, a 3-D acoustical spatial locater, and a personal computer. It displays within each image the line of intersection of two image planes, a reference image, and a live image. This display guides and documents image positioning. The scanner's 3-D data also provide the potential for computergraphic modeling of organs, the ability to calculate volumes using nonparallel, nonintersecting image planes, and the capability for 3-D color flow mapping and measurement of Doppler angle.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 50 条
  • [1] REAL-TIME 3-DIMENSIONAL RECONSTRUCTION OF INTRAVASCULAR ULTRASOUND IMAGES OF ILIAC ARTERIES
    ROSENFIELD, K
    KAUFMAN, J
    PIECZEK, A
    LANGEVIN, RE
    RAZVI, S
    ISNER, JM
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (03): : 412 - 415
  • [2] RECENT PROGRESS IN A REAL-TIME 3-DIMENSIONAL DISPLAY
    GOETZ, GG
    MUELLER, RK
    SHUPE, DM
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1973, ED20 (11) : 1020 - 1027
  • [3] INTERACTIVE REAL-TIME 3-DIMENSIONAL COMPUTER-GRAPHICS
    LANGRIDGE, R
    BIOPHYSICAL JOURNAL, 1984, 45 (02) : A132 - A132
  • [4] Interactive volume rendering of real-time three-dimensional ultrasound images
    Kuo, Johnny
    Bredthauer, Gregory R.
    Castellucci, John B.
    von Ramm, Olaf T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (02) : 313 - 318
  • [5] 3-DIMENSIONAL INFORMATION FROM REAL-TIME ENCODED IMAGES
    TOBIN, KW
    BRENIZER, JS
    MAIT, JN
    OPTICAL ENGINEERING, 1990, 29 (01) : 52 - 57
  • [6] REAL-TIME 3-DIMENSIONAL DISPLAY BASED ON THE PARTIAL PIXEL ARCHITECTURE
    JONES, MW
    NORDIN, GP
    KULICK, JH
    LINDQUIST, RG
    KOWEL, ST
    OPTICS LETTERS, 1995, 20 (12) : 1418 - 1420
  • [7] Interactive rendering of real-time volumetric ultrasound images
    Bredthauer, GR
    von Ramm, OT
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 524 - 526
  • [8] VISTANET - INTERACTIVE REAL-TIME CALCULATION AND DISPLAY OF 3-DIMENSIONAL RADIATION-DOSE - AN APPLICATION OF GIGABIT NETWORKING
    ROSENMAN, JG
    CHANEY, EL
    CULLIP, TJ
    SYMON, JR
    CHI, VL
    FUCHS, H
    STEVENSON, DS
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (01): : 123 - 129
  • [9] 3-Dimensional Elastic Registration System of Prostate Biopsy Location by Real-Time 3-Dimensional Transrectal Ultrasound Guidance With Magnetic Resonance/Transrectal Ultrasound Image Fusion
    Ukimura, Osamu
    Desai, Mihir M.
    Palmer, Suzanne
    Valencerina, Samuel
    Gross, Mitchell
    Abreu, Andre L.
    Aron, Monish
    Gill, Inderbir S.
    JOURNAL OF UROLOGY, 2012, 187 (03): : 1080 - 1086
  • [10] REAL-TIME SYSTEM FOR ACCURATE 3-DIMENSIONAL POSITION DETERMINATION AND VERIFICATION
    HUSSAIN, B
    KABUKA, MR
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1990, 6 (01): : 31 - 43