摘要
A remote flow cell has been interfaced to a scanning uv-visible absorbance detector for the detection of gas chromatography (GC) analytes. The unique optical bench, detection scheme, and thermal control allow low-noise operation at flow cell temperatures of 350-degrees-C. Noise of 1 x 10(-5) a.u. (peak to peak over a 1-min period) and drift at the 1 x 10(-4) a.u./h level facilitate detection of coumarin in the gas phase at 40 pg/s. Flow cell volume was optimized for use with capillary GC columns. An effective band pass of < 3 nm provides spectral resolution which shows solute absorbance fine structure to aid in compound identification.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [1] CAPILLARY GAS-CHROMATOGRAPHY WITH ULTRAVIOLET SPECTROMETRIC DETECTION
    NOVOTNY, M
    SCHWENDE, FJ
    HARTIGAN, MJ
    PURCELL, JE
    ANALYTICAL CHEMISTRY, 1980, 52 (04) : 736 - 740
  • [2] GC-UV - CAPILLARY GAS-CHROMATOGRAPHY WITH RAPID SCANNING ULTRAVIOLET DETECTION
    BORNHOP, DJ
    WANGSGAARD, JG
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (05): : 344 - 347
  • [3] RAPID SCANNING UV-VIS DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY USING A REMOTE FLOW CELL
    HACKETT, M
    WANG, H
    MILLER, GC
    BORNHOP, DJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 60 - ENVR
  • [4] GASOLINE ANALYSIS BY RAPID SCANNING ABSORBENCY DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY
    BORNHOP, DJ
    VERGA, GR
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (05) : 194 - 199
  • [5] ULTRAVIOLET-VISIBLE DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY AND COMBINED ULTRAVIOLET MASS-SPECTROMETRY USING A REMOTE FLOW CELL
    HACKETT, M
    WANG, HL
    MILLER, GC
    BORNHOP, DJ
    JOURNAL OF CHROMATOGRAPHY A, 1995, 695 (02) : 243 - 257
  • [6] INDIRECT FLUORESCENCE DETECTION IN CAPILLARY GAS-CHROMATOGRAPHY
    BAGHERI, H
    CREASER, CS
    ANALYTICA CHIMICA ACTA, 1990, 233 (02) : 303 - 306
  • [7] DETECTION OF PICOGRAM LEVELS OF SUFENTANIL BY CAPILLARY GAS-CHROMATOGRAPHY
    WELDON, ST
    PERRY, DF
    CORK, RC
    GANDOLFI, AJ
    ANESTHESIOLOGY, 1985, 63 (06) : 684 - 687
  • [8] ION MOBILITY DETECTION AFTER CAPILLARY GAS-CHROMATOGRAPHY
    STLOUIS, RH
    SIEMS, WF
    HILL, HH
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1988, 6 (09): : 811 - 814
  • [9] THE RAPID SCANNING SPECTROMETER AS A MULTICHANNEL DETECTION FOR GAS-CHROMATOGRAPHY
    MULLIGAN, KJ
    CARUSO, JA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 148 - ANYL
  • [10] SELECTIVITY IN CAPILLARY GAS-CHROMATOGRAPHY
    BLOMBERG, L
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (04): : 208 - 208