Development of Cell Phone Application for Blood Glucose Self-Monitoring Based on ISO/IEEE 11073 and HL7 CCD

被引:11
|
作者
Park, Hyun Sang [1 ]
Cho, Hune [1 ]
Kim, Hwa Sun [2 ]
机构
[1] Kyungpook Natl Univ, Dept Med Informat, Daegu, South Korea
[2] Daegu Haany Univ, Dept Med Informat Technol, 1 Hanuidae Ro, Gyongsan 712715, South Korea
关键词
Blood Glucose Self-Monitoring; Cell Phones; Health Communication;
D O I
10.4258/hir.2015.21.2.83
中图分类号
R-058 [];
学科分类号
摘要
Objectives: The objectives of this research were to develop and evaluate a cell phone application based on the standard protocol for personal health devices and the standard information model for personal health records to support effective blood glucose management and standardized service for patients with diabetes. Methods: An application was developed for Android 4.0.3. In addition, an IEEE 11073 Manager, Medical Device Encoding Rule, and Bluetooth Health Device Profile Connector were developed for standardized health communication with a glucometer, and a Continuity of Care Document (CCD) Composer and CCD Parser were developed for CCD document exchange. The developed application was evaluated by five healthcare professionals and 87 users through a questionnaire comprising the following variables: usage intention, effort expectancy, social influence, facilitating condition, perceived risk, and voluntariness. Results: As a result of the evaluation of usability, it was confirmed that the developed application is useful for blood glucose self-monitoring by diabetic patients. In particular, the healthcare professionals stated their own views that the application is useful to observe the trends in blood glucose change through the automatic function which records a blood glucose level measured using Bluetooth function, and the function which checks accumulated records of blood glucose levels. Also, a result of the evaluation of usage intention was 3.52 +/- 0.42 out of 5 points. Conclusions: The application developed by our research team was confirmed by the verification of healthcare professionals that accurate feedback can be provided to healthcare professionals during the management of diabetic patients or education for glucose management.
引用
收藏
页码:83 / 94
页数:12
相关论文
共 50 条
  • [1] A study on HL7 standard message for healthcare system based on ISO/IEEE 11073
    Oh, Am-Suk
    International Journal of Smart Home, 2015, 9 (06): : 113 - 118
  • [2] Interoperability of Medical Device Information and the Clinical Applications: An HL7 RMIM based on the ISO/IEEE 11073 DIM
    Yuksel, Mustafa
    Dogac, Asuman
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 557 - 566
  • [3] ISO/IEEE 11073, IHE, and HL7: Fostering Standards-Based Safe, Reliable, Secure and Interoperable Biomedical Technologies
    Sloane, Elliot B.
    Thalassinidis, Angelo
    Silva, Ricardo
    IEEE SOUTHEASTCON 2018, 2018,
  • [4] ISO/IEEE 11073, IHE, and HL7: Fostering Standards-Based Safe, Reliable, Secure and Interoperable Biomedical Technologies
    Sloane, Elliot B.
    Thalassinidis, Angelo
    Silva, Ricardo J.
    IEEE SOUTHEASTCON 2018, 2018,
  • [5] Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose
    La Belle, Jeffrey T.
    Adams, Anngela
    Lin, Chi-En
    Engelschall, Erica
    Pratta, Breanna
    Cook, Curtiss B.
    CHEMICAL COMMUNICATIONS, 2016, 52 (59) : 9197 - 9204
  • [6] Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
    Lee, Sungkee
    Do, Hyoungho
    HEALTHCARE INFORMATICS RESEARCH, 2018, 24 (01) : 46 - 52
  • [7] Development of the portable blood glucose meter for self-monitoring of blood glucose
    Li, Qi
    Yuan, Jingqi
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6735 - 6738
  • [8] Design and Development of a Ubiquitous Healthcare Monitoring System Based on Android Platform and ISO/IEEE 11073 Standards
    Chen, Xianxiang
    Bao, Xun
    Fang, Zhen
    Xia, Shanhong
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 1165 - 1168
  • [9] Development and testing of the barriers to self-monitoring blood glucose scale
    Jones, PM
    Remley, C
    Engberg, RA
    DIABETES EDUCATOR, 1996, 22 (06): : 609 - 616
  • [10] Clinical application and challenges of blood glucose measurement technology for self-monitoring
    Heinemann, Lutz
    Koschinsky, Theodor
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 : S27 - S34