GAS FLOW-RATE MEASUREMENTS FOR LEAK CALIBRATION

被引:12
|
作者
BERGOGLIO, M
CALCATELLI, A
RUMIANO, G
机构
关键词
D O I
10.1016/0042-207X(95)00033-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Results concerning the calibration of metal capillary tubes of the linear and crimped types with different inert testing gases from 3 x 10(-8) Pa m(3) s(-1) to 3 x 10(-5) Pa m(3) s(-1) (1 x 10(-11) mol s(-1)-1 x 10(-8) mol s(-1)) are presented. A primary flowmeter connected to a dynamic expansion system is used as a reference. With gas flow rates above 5 x 10(-7) Pa m(3) s(-1) (2 x 10(-10) mol (s-)1), direct comparisons are made, whereas for flow rates below that value the reduction method is applied. The unknown gas flow rates and those from the flowmeter are compared by means of a quadrupole mass spectrometer. These capillaries, after appropriate calibration, can be used as secondary reference leaks in the stated range with total uncertainty between 1.3 x 10(-2) and 9 x 10(-3) and the final object of this work is to provide a leak calibration service to users.
引用
收藏
页码:763 / 765
页数:3
相关论文
共 50 条
  • [1] Leak rate calibration with gas flow standard apparatus
    Zhang, DX
    Liu, SL
    Li, DT
    Yang, M
    Liu, QA
    Li, WK
    VACUUM, 1996, 47 (6-8) : 515 - 517
  • [2] A NOTE ON FLOW-RATE AND LEAK RATE UNITS
    EHRLICH, CD
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1986, 4 (05): : 2384 - 2385
  • [3] APPLICATION OF SHORT-LIVED TRACERS TO FLOW-RATE MEASUREMENTS AND LEAK DETECTION
    GUIZERIX, J
    CORNUET, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (SEP): : 524 - &
  • [4] Very low gas flow measurements for UHV/XHV and leak calibration
    Li Detian
    Cheng Yongjun
    Feng Yan
    Xi Zhenhua
    Zhao Lan
    METROLOGIA, 2013, 50 (01) : 15 - 19
  • [5] GAS FLOW-RATE METROLOGY
    MATTINGLY, GE
    1988 WORKSHOP AND SYMPOSIUM, TECHNICAL PRESENTATIONS : COMPETITIVENESS IN A WORLD MARKET, 1988, : 319 - 337
  • [6] The Joule-Thomson effect in natural gas flow-rate measurements
    Maric, I
    FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (06) : 387 - 395
  • [7] EVALUATION OF LEAK FLOW-RATE AND JET IMPINGEMENT RELATED TO LEAK BEFORE BREAK
    YANO, T
    MATSUSHIMA, E
    OKAMOTO, A
    NUCLEAR ENGINEERING AND DESIGN, 1989, 111 (01) : 197 - 205
  • [8] STRAIGHT PIPING LENGTHS FOR FLOW-RATE MEASUREMENTS
    KREMLEVSKII, PP
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (08): : 1189 - +
  • [9] MAIN COMPONENTS AND PERFORMANCES OF THE IMGC CALIBRATION FACILITIES FOR LIQUID-HELIUM FLOW-RATE MEASUREMENTS
    RIVETTI, A
    MARTINI, G
    GORIA, R
    LOREFICE, S
    CRYOGENICS, 1987, 27 (02) : 77 - 80
  • [10] MEASUREMENT OF FLOW-RATE BY MEANS OF TRACER GAS
    NAKAGAWA, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1984, 70 (13): : 1084 - 1084