EFFECTS ON COAGULATION AND FIBRINOLYSIS WITH REDUCED VERSUS FULL SYSTEMIC HEPARINIZATION AND HEPARIN-COATED CARDIOPULMONARY BYPASS

被引:1
|
作者
OVRUM, E [1 ]
BROSSTAD, F [1 ]
HOLEN, EA [1 ]
TANGEN, G [1 ]
ABDELNOOR, M [1 ]
机构
[1] UNIV OSLO,NATL HOSP,INTERNAL MED RES INST,N-0027 OSLO,NORWAY
关键词
COAGULATION; FIBRINOLYSIS; HEPARIN; CARDIOPULMONARY BYPASS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Extracorporeal circulation with circuits coated with surface-bound heparin has allowed reduced levels of systemic heparinization. Clinical benefits have included reduced postoperative bleeding and less homologous blood usage. However, the effects on the hemostatic and fibrinolytic systems have remained in part unknown. Methods and Results Indications of thrombin generation, platelet activation, and fibrinolytic activity were investigated in patients undergoing coronary artery bypass surgery. Two groups were perfused with cardiopulmonary bypass (CPB) circuits completely coated with surface-bound heparin: one group with low systemic heparin dose (activated clotting time [ACT] >250 seconds; n=17) and a second group having a full heparin dose (ACT >480 seconds; n=18). A third control group was perfused with ordinary uncoated circuits and full heparin dose (n=17). The plasma level of thrombin-antithrombin complex and prothrombin fragment 1.2 increased in all groups during bypass, and somewhat more in both the heparin-coated groups toward the end of CPB, compared with the control group (P<.01). However, the increase during CPB was minimal compared with the major elevation observed 2 hours after surgery in all groups. Platelet release of beta-thromboglobulin increased in all groups (P<.01) during CPB and significantly more in the high-dose group compared with the other two groups (P=.03). Fibrinolytic activities were similar in all groups, and there were no indications of major consumption of coagulation factors. Conclusions Reduced systemic heparinization (ACT >250 seconds) in patients having extracorporeal circulation with completely heparin-coated circuits did not lead to increased thrombogenicity. Thrombin formation remained within low ranges during CPB compared with patients receiving a full heparin dose and with the major elevations observed after surgery.
引用
收藏
页码:2579 / 2584
页数:6
相关论文
共 50 条
  • [1] Coagulofibrinolysis during heparin-coated cardiopulmonary bypass with reduced heparinization
    Kumano, H
    Suehiro, S
    Hattori, K
    Shibata, T
    Sasaki, Y
    Hosono, M
    Kinoshita, H
    ANNALS OF THORACIC SURGERY, 1999, 68 (04): : 1252 - 1256
  • [2] Complete heparin-coated (CBAS) cardio-pulmonary bypass and reduced systemic heparin dose; Effects on coagulation and fibrinolysis
    Ovrum, E
    Brosstad, F
    Holen, EA
    Tangen, G
    Abdelnoor, M
    Oystese, R
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (06) : 449 - 455
  • [3] Cardiopulmonary bypass with heparin-coated circuits and reduced systemic anticoagulation
    Kuitunen, AH
    Heikkila, LJ
    Salmenpera, MT
    ANNALS OF THORACIC SURGERY, 1997, 63 (02): : 438 - 444
  • [4] PLATELET AND COAGULATION ACTIVATION BY HEPARIN-COATED CARDIOPULMONARY BYPASS SYSTEMS
    KOTTKEMARCHANT, K
    BORSCH, J
    MCCARTHY, P
    LAASCH, C
    BROOKS, L
    MUEHRCKE, D
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1344 - 1344
  • [5] CARDIOPULMONARY BYPASS WITHOUT SYSTEMIC HEPARINIZATION - PERFORMANCE OF HEPARIN-COATED OXYGENATORS IN COMPARISON WITH CLASSIC MEMBRANE AND BUBBLE OXYGENATORS
    VONSEGESSER, LK
    TURINA, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 98 (03): : 386 - 396
  • [6] REDUCED COMPLEMENT AND GRANULOCYTE ACTIVATION WITH HEPARIN-COATED CARDIOPULMONARY BYPASS
    FOSSE, E
    MOEN, O
    JOHNSON, E
    SEMB, G
    BROCKMEIER, V
    MOLLNES, TE
    FAGERHOL, MK
    VENGE, P
    ANNALS OF THORACIC SURGERY, 1994, 58 (02): : 472 - 477
  • [7] EXPERIMENTAL EVALUATION OF HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT WITH LOW SYSTEMIC HEPARINIZATION AND HIGH-DOSE APROTININ
    VONSEGESSER, LK
    WEISS, BM
    PASIC, M
    LESKOSEK, B
    VONFELTEN, A
    PEI, P
    TURINA, M
    THORACIC AND CARDIOVASCULAR SURGEON, 1991, 39 (05): : 251 - 256
  • [8] No benefit of reduced heparinization in thoracic aortic operation with heparin-coated bypass circuits
    Olsson, C
    Siegbahn, A
    Haldén, E
    Nilsson, B
    Venge, P
    Thelin, S
    ANNALS OF THORACIC SURGERY, 2000, 69 (03): : 743 - 749
  • [9] USE OF HEPARIN-COATED CARDIOPULMONARY BYPASS
    JONES, DR
    HILL, RC
    HOLLINGSED, MJ
    STULLKEN, E
    GRAEBER, GM
    GUSTAFSON, RA
    MURRAY, GF
    ANNALS OF THORACIC SURGERY, 1993, 56 (03): : 556 - 558
  • [10] The antithrombin III-saving effect of reduced systemic heparinization and heparin-coated circuits
    Ranucci, M
    Cazzaniga, A
    Soro, G
    Isgrò, G
    Frigiola, A
    Menicanti, L
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (03) : 316 - 320