MATERNAL AND FETAL CONCENTRATION OF MORPHINE AFTER INTRATHECAL ADMINISTRATION DURING LABOR

被引:24
|
作者
BONNARDOT, JP
MAILLET, M
COLAU, JC
MILLOT, F
DELIGNE, P
机构
[1] HOP TENON, DEPT ANESTHESIE REANIMAT, F-75970 PARIS 20, FRANCE
[2] HOP TENON, SERV GYNECOL OBSTET, F-75970 PARIS 20, FRANCE
[3] HOP TENON, BIOCHIM LAB, F-75970 PARIS 20, FRANCE
关键词
D O I
10.1093/bja/54.5.487
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Healthy women (25) in labor received morphine 1-1.75 mg in normal saline intrathecally. The residual pain was evaluated on a scale for 0-5 at 10 (score 2.5) and 25 min (score 1.5). After delivery the maternal and fetal plasma morphine concentrations were measured by radioimmunoassay in 14 parturients. Of the 25 women, 23 had vaginal deliveries, 20 of them without forceps. The maternal and fetal plasma concentrations of morphine were .gtoreq. 6 ng/ml. The intrathecal (but not extradural) administration of morphine is effective and could provide an alternative for pain relief in labor.
引用
收藏
页码:487 / 489
页数:3
相关论文
共 50 条
  • [1] INTRATHECAL ADMINISTRATION OF MORPHINE FOR THE RELIEF OF PAINS IN LABOR AND ESTIMATION OF MATERNAL AND FETAL PLASMA-CONCENTRATION OF MORPHINE
    HEE, P
    SORENSEN, SS
    BOCK, JE
    FERNANDES, A
    STEENTOFT, A
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1987, 25 (03): : 195 - 201
  • [2] MATERNAL AND FETAL CONCENTRATIONS OF MORPHINE AFTER EPIDURAL ADMINISTRATION DURING LABOR
    NYBELLLINDAHL, G
    CARLSSON, C
    INGEMARSSON, I
    WESTGREN, M
    PAALZOW, L
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 139 (01) : 20 - 21
  • [3] PLASMA MORPHINE CONCENTRATION AFTER INTRAMUSCULAR, EPIDURAL AND INTRATHECAL ADMINISTRATION
    CHAUVIN, M
    SAMII, K
    SCHERMANN, JM
    SANDOUK, P
    BOURDON, R
    VIARS, P
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1981, 25 : 82 - 82
  • [4] PLASMA MORPHINE CONCENTRATION AFTER INTRATHECAL ADMINISTRATION OF LOW-DOSES OF MORPHINE
    CHAUVIN, M
    SAMII, K
    SCHERMANN, JM
    SANDOUK, P
    BOURDON, R
    VIARS, P
    BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (10) : 1065 - 1067
  • [5] PLASMA-CONCENTRATION OF MORPHINE AFTER IM, EXTRADURAL AND INTRATHECAL ADMINISTRATION
    CHAUVIN, M
    SAMII, K
    SCHERMANN, JM
    SANDOUK, P
    BOURDON, R
    VIARS, P
    BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (09) : 911 - 913
  • [6] FETAL AND MATERNAL EFFECTS OF BICARBONATE ADMINISTRATION DURING LABOR
    CLARK, RB
    STEPHENS, SR
    GREIFENSTEIN, FE
    ANESTHESIA AND ANALGESIA CURRENT RESEARCHES, 1971, 50 (05): : 713 - +
  • [7] INTRATHECAL ADMINISTRATION OF HYPERBARIC MORPHINE FOR THE RELIEF OF PAIN IN LABOR
    ABBOUD, TK
    SHNIDER, SM
    DAILEY, PA
    RAYA, JA
    SARKIS, F
    GROBLER, NM
    SADRI, S
    KHOO, SS
    DESOUSA, B
    BAYSINGER, CL
    MILLER, F
    BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (12) : 1351 - 1360
  • [8] HUMAN FETAL INSULIN RESPONSE AFTER ACUTE MATERNAL GLUCOSE ADMINISTRATION DURING LABOR
    TOBIN, JD
    ROUX, JF
    SOELDNER, JS
    PEDIATRICS, 1969, 44 (5P1) : 668 - &
  • [9] THE DEGREE OF ANALGESIA CORRELATES TO SPINAL MORPHINE CONCENTRATION AFTER INTRATHECAL ADMINISTRATION IN RATS
    GUSTAFSSON, LL
    POST, C
    ACTA PHARMACOLOGICA ET TOXICOLOGICA, 1986, 58 (04): : 243 - 248
  • [10] EFFECT OF INTRATHECAL MORPHINE DURING LABOR ON MATERNAL PLASMA BETA-ENDORPHIN LEVELS
    ABBOUD, TK
    GOEBELSMANN, U
    RAYA, J
    HOFFMAN, DI
    DESOUSA, B
    BRIZGYS, RV
    KOTELKO, DM
    SHNIDER, SM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 149 (07) : 709 - 710